Technical Data
Rated Lifting Load
Lifting Range
Max. load when using
the farm jack as a safety
stand. Use a ½" bolt as
an additional safety
device.
Total Weight of the Farm Jack
Explanation
At a load of 2000 kg the lifting range must be up to max. 300 mm.
At a load of 1600 kg, the lifting range must be up to max. 500 mm.
If the height is more than 500 mm, the load must not exceed 500 kg.
All manuals and user guides at all-guides.com
up to max. 300 mm
up to max. 500 mm
H >= 500 mm
Using
20
400 kg
130 – 1060 mm
2000 kg
1600 kg
500 kg
14.5 kg