Télécharger Imprimer la page

Blanco 4L EU Instructions De Montage Et D'utilisation page 11

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 15
EN
INSTALLATION
Malfunction, property damage
Do not use any hose extensions to the boiler – neither at the outlet nor at the
inlet.
Malfunction
The boiler will not work if you invert the water connections.
Damage, scalding, injury
The supplied safety assembly module, and only the supplied module, must
be installed directly upstream of the boiler inlet in the correct direction of
fl ow. It must be installed in such a way that it won't cause a blockage in
the connection between the safety assembly module and the boiler inlet.
4.
Preparation work
Water installation
 Flush the water pipelines thoroughly.
Fittings
 Use appropriate BLANCO hot water fittings only. Other fittings are not permitted.
Connecting to power
WARNING - electric shock
Carry out all electrical connection and installation work in accordance with regulations.
 The connection cable with EU plug is designed for a safety socket outlet CEE 7
type F. The UK connection cable is designed for a safety socket outlet type BS
1363. It must be freely accessible after the boiler is installed.
 Do not plug the boiler into a multiple socket outlet.
 It is not permitted to use a direct (permanently installed) electrical line to connect to
the power network.
5.
Installation location
Material damage
The system must be installed in a frostproof room only.
 Install the boiler in an upright position and close to the tapping point. The boiler
is suitable for installation under worktops. The boiler must not be operated in a
horizontal position.
20
All manuals and user guides at all-guides.com
INSTALLATION
6.
Important
 See separate instructions enclosed in the packaging.
OPERATION
7.
The hot water boiler heats up drinking water electrically. The electronic temperature
controller controls the electric heating and switches the boiler off.
The hot water boiler is protected against frost if it is connected to the power supply.
However, this does not protect the fi tting and water connections.
8.
Safety assembly module function test
 The safety assembly module must be tested to ensure it functions correctly after
the boiler is switched on: A small amount of water must drip into the drip cup from
the safety assembly module while the boiler is heating up (boiler LED fl ashes red).
 If no water drips out of the safety assembly module, switch off the boiler and
check installation.
 Water will no longer drip out of the safety assembly module once the boiler has
fi nished heating up (LED lights up red permanently).
Assembly
Malfunction, property damage
Always operate the boiler with the supplied safety assembly module installed
correctly at the boiler inlet only.
Boiler description
Commissioning
WARNING - electric shock
Only a trained technician may put the boiler into operation and they must
comply with safety regulations in doing so.
Property damage, malfunction
Do not switch on the boiler if it is not correctly installed and is not fi lled to
capacity with water; otherwise, you may damage the fi tting or the boiler.
EN
21

Publicité

loading

Produits Connexes pour Blanco 4L EU

Ce manuel est également adapté pour:

4l uk