LEAK TEST
• Perform all tests outdoors.
• Extinguish all open flames.
• NEVER leak test when smoking.
• Do not use the fire pit until all connections have been leak tested and do not leak.
Hose / Regulator Connection
1. Make 2-3 oz. of leak test solution (one part liquid dish-washing detergent and three parts water).
2. Apply several drops of solution where hose attaches to regulator.
3. Apply several drops of solution where regulator connects to cylinder.
4. Make sure all fire pit and light valves are "OFF".
5. Turn cylinder valve ON.
If bubbles appear at any connection, there is a leak.
1. Turn cylinder valve "OFF".
2. If leak is at hose/regulator connection: tighten connection and perform another leak test. If bubbles continue
appearing, the hose should be returned to the place of purchase.
3. If leak is at regulator/cylinder valve connection: disconnect, reconnect, and perform another leak test. If
you continue to see bubbles after several attempts, cylinder valve is defective and should be returned to
cylinder place of purchase.
If NO bubbles appear at any connection, the connections are secure.
NOTE: Whenever gas connections are loosened or removed, you must perform a complete leak test. Complete
installation.