Télécharger Imprimer la page

Tritech T9 Manuel Du Propriétaire page 43

Publicité

Les langues disponibles

Les langues disponibles

PRESSURE RELIEF PROCEDURE
!! IMPORTANT !!
The sprayer's pressure must be manually relieved to prevent sprayer from starting or spraying
fluid accidentally. Fluid under high pressure can be injected through skin and cause serious injury.
To reduce risk of injury from injection, splashing fluid, or moving parts, please use the following
Pressure Relief Procedure whenever you:
• Are instructed to relieve pressure
• Stop spraying
• Have to check or service your equipment
• Are installing or cleaning the spray tip
PRESSURE RELIEF PROCEDURE
1. Turn the pressure control knob all the way to the left to stop the unit from pumping.
2. Turn the On/Off switch to the OFF position.
3. Unplug the power cord from the wall.
4. Hold the metal part of the gun firmly to a grounded metal container and trigger the gun to
relieve the pressure.
5. Engage the trigger lock.
6. Open the prime valve (The valve is in prime position when the handle is pointing down) and
leave it open until you are ready to spray again. If you are going to store your unit for an
extended period, turn the prime / spray valve to the spray position. (The valve is in the spray
position when the handle is pointing to the front)
43

Publicité

loading