INSTALLATION & OPERATION
INSTALLATION & OPERATION
Bargraph Display
Use SCALE on LEFT SIDE for ON times
(5 seconds to 60 minutes)
Use SCALE on RIGHT SIDE for OFF
times
(1 minute to 12 hours)
Light sensor (photocell)
The photocell detects a NIGHT condition when it senses darkness for
a minimum period of 8 seconds.
The photocell detects a DAY condition when it senses light for a
minimum period of 8 seconds
In order to disable DAY or NIGHT operation, set corresponding ON time to
"zero"
- turn knob counter clockwise until all bars are OFF when setting
DAY ON or NIGHT ON times.
The bottom bar of display is flashing at the end of a cycle. The bar will
flash for 2 seconds at the end of an ON time, and for 30 seconds at the
end of an OFF time.
DAY AND NIGHT DETECTION
DISABLING OPERATION
BOTTOM BAR IS BLINKING
120V Output plug