ALARM TYPE
Alarm type 1st number
Alarm type 2nd number
Alarm type 3rd number
Alarm type 4th number
Alarm type LMS
Alarm type Test alarm
OTHER CODES
Repeated alarm
External inputs
- Function
External inputs
- Input N/O or N/C
Unit number
Alarm button delay time
Outputs (Relay)
[DOCSxxxx] SL6 Quick guide 201811.indd 32
All manuals and user guides at all-guides.com
CODE DATA
*41*
- - #
*42*
- - #
*43*
- - #
*44*
- - #
*45*
- - #
*46*
- - #
CODE DATA
*39*
-#
*73*
- - #
*74*
- - #
*82*
- #
*87*
- - #
*88*
- - #
32
COMMENTS
Only when using CPC as alarm protocol
Normally 10 or 27, check with your alarm
company!
Normally 17
Normally 26
COMMENTS
Repeated alarms: Battery failure, Mic/
Speaker failure, Stuck button.
Alarm action repeats every 24h until the
problem is resolved.
0 = Off (default)
1 = On
The first number selects the input, i.e. Input 1
or Input 2. The second number selects the
function.
0 = None
1 = Filter
2 = LMS/SMS
3 = Clear/Maintenance
4 = Fire Mode (default = input 2)
5 = Alarm Button (default = input 1)
6 = Call Delay
The first number selects the input, i.e. Input 1
or Input 2.
The second number selects N/O (0) or N/C
(1).
Defult = N/O
Unit number [0] is set by default, and means
that the unit will respond immediately.
00-25 seconds. Default = 05
The first number selects the relay output,
i.e. Relay 1 or Relay 2. The second number
selects the function. For SW 4.00 or later, the
following parameters are used:
0 = Alarm status outputs (default relay 1)
1 = Battery failure (default relay 2)
2 = Pictogram (Relay 1: yellow, relay 2:
green)
3 = Activate with DTMF 8/9
(relay 1 - DTMF 8, relay 2 - DTMF 9)
4 = Manual reset
5 = Emergency call failure
6 = System failure
7 = Emergency bell