Declaration Of Conformity - D+H KA 66-TW-DF Notice Originale

Dispositif conçu pour motorisation à chaîne pour l'ouverture et la fermeture électromotorisées de fenêtres à ouverture à la française
Masquer les pouces Voir aussi pour KA 66-TW-DF:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Mounting informations
The stiff backside of the chain
(cable outlet at the top) must
point to the top.
û
Locking force adjustment
If factory-set locking pressure of aprox. 150 N is not
sufficient to close the window, it can be infinitely
increased up to aprox. 250 N.
Put in covering stopper after adjustment.
Locking force adjustment
Ø 6 mm
approx. 150 N
99.824.41 1.4/05/18
Mount the drives mechanical
stress-free. With that, more even
load distribution is ensured on
all the drive chains.
ü
=
approx. 250 N

Declaration of Conformity

We declare under our sole responsibility that the
product described under "Technical Data" is in
conformity with the following directives:
2014/30/EU, 2014/35/EU
Technical file at:
D+H Mechatronic AG, D-22949 Ammersbek
Dirk Dingfelder
Member of the Board
31.03.2016
Disposal
Electrical devices, accessories, batteries and packa-
ging should be sorted for environmental-friendly
recycling. Do not dispose electrical devices and
batteries into household waste!
Only for EC countries:
According the European Guideline 2012/19/EU for
waste electrical and electronic equipment and its
implementation into national right, electrcal devices
that are no longer usable must be collected separa-
tely and disposed of in an environmentally correct
manner.
English
If after mounting, the measure X
is as bigger as 23 mm, null
balance with software SCS is
neccesary. Closure Ranges will
shift in relation to new zero
point.
≥ 23 mm ? X
Maik Schmees
Authorized signatory, Technical Director
KA 66 TW-DF
7/16

Publicité

Table des Matières
loading