Jandy
Variable-Speed Pumps, DV/DVS Models
®
Distance from Sub-Panel
Inverse - Time Circuit Breaker or
Branch Fuse AMPs
Pump Model
Class: CC, G, H, J, K, RK, or T
230 VAC
VSFHP130DV
15A
VSFHP130DVS
VSFHP165DV
20A
VSFHP165DVS
VSFHP185DV
20A
VSFHP185DVS
*Assumes three (3) copper conductors in a buried conduit and 3% maximum voltage loss in branch circuit. All National Electrical Code
local codes must be followed. Table shows minimum wire size and branch fuse recommendations for a typical installation per NEC.
Table 2.
Minimum Wire Size and Minimum Overcurrent Protection*
Base Configuration
1. Pump without Base
2. Pump with Base
3. Pump with Base
and Spacers
4. Pump with Small +
Large Base
Table 3.
Adjustable Base Dimensions
(VS FloPro
TM
1.
Using a hand cutter tool, cut the plastic bars
connecting the top and bottom sets of spacers, as
shown in Figure 6.
2.
Push the two top spacers and two bottom spacers
out of the base.
3.
Align the pins in the four spacers with the holes in
the base. Snap the spacers into place. See Figure 7.
Figure 6.
Cut Sets of Spacers Out of Base
|
Installation & Operation Manual
0-50 feet (15 meters)
115 VAC
230 VAC
14 AWG
20A
(2.1mm
30A
12 AWG
30A
12 AWG
Suction
Pump
Side
Height
Height
7 3/4"
12 3/4"
8 7/8"
13 7/8"
9 1/8"
14 1/8"
10 3/4"
15 3/4"
Models Only)
Cut
spacers
at X.
50-100 feet (15-30 meters)
Voltage
Voltage
115 VAC
230 VAC
12 AWG
12 AWG
)
(3.3mm
)
(3.3mm
)
2
2
2
10 AWG
12 AWG
10 AWG
12 AWG
Figure 7.
Snap Spacers into Place
3.2
Electrical Installation
3.2.1
Voltage Checks
The correct voltage, as specified on the pump data plate,
is necessary for proper performance and long motor
life. Incorrect voltage will decrease the pump's ability to
perform and could cause overheating, reduce the motor life,
and result in higher electric bills.
It is the responsibility of the electrical installer to provide
data plate operating voltage to the pump by ensuring
proper circuit sizes and wire sizes for this specific
application.
The National Electrical Code
requires all pool pump circuits be protected with a
Ground Fault Interrupter (GFCI). Therefore, it is also
the responsibility of the electrical installer to ensure that
the pump circuit is in compliance with this and all other
applicable requirements of the National Electrical Code
(NEC) and any other applicable installation codes.
Failure to provide data plate voltage (+/- 10%) during
operation will cause the motor to overheat and may void the
warranty.
Page 11
ENGLISH
100-200 feet (30-60 meters)
Voltage
115 VAC
230 VAC
10 AWG
10 AWG
(5.3mm
)
(5.3mm
)
2
2
8 AWG
10 AWG
8 AWG
10 AWG
®
(NEC
, NFPA-70
®
®
CAUTION
115 VAC
6 AWG
(5.3mm
)
2
6 AWG
6 AWG
®
(NEC
) and
)
®