Pre-Installation (continued)
PLANNING INSTALLATION
Number of people required: 2 or more
Carefully check the range hood for damage and for missing parts
prior to installation . If there is any damage or if you are missing parts,
do not proceed with the installation . Report damage and missing
parts immediately . Do not dispose of packaging before you are
satisfied with your new range hood.
1 . Before installation, measure all distances to ensure the proper
position of the range hood (A) .
- The minimum distance (1) from the cooking surface to the
range hood is 18 in. (458 mm). If your range specifies a
different distance, use the greater distance of the two . For
best performance, this distance (1) should not exceed 25 in .
(635 mm) .
- Dimension (2) should be at least 762 mm (30 in). The range
hood should be approximately the same size as the cook top .
2 . If the bottom of the cabinet (3) above the location where the range
hood is to be installed is recessed, attach appropriately sized wood
filler strips (4) on each side using wood screws.
3 . Screws are provided to secure the range hood to most types of
cabinets, but consult a qualified installer to verify that the supplied
screws are suitable for your cabinets .
4 . Put a thick, protective covering over your counter, cooktop, or
range to protect it from damage and dirt during installation .
Remove any hazardous objects around the area .
VENTING OPTIONS:
a . Determine if your existing venting system is top venting or back venting, and ensure that the openings in the cabinet or wall for the
damper and for power access are in appropriate locations and are of appropriate sizes, as per Fig . 3 if it is top venting or Fig . 4 if it is
back venting . For top venting option (Fig . 3), if you are using the round adapter, the opening should be A and B only . If you are using
the rectangular damper, opening should be B and C only .
b . If this is a new installation, choose the venting method that suits your needs . Cut out openings for the damper and for power access
in the cabinet bottom or exterior wall, depending on the direction of venting chosen .
2.04"
(52 mm)
7
Please contact cs@conglomkb.com or 1-877-333-0098 for further assistance .
WARNING:
Always wear safety goggles and gloves during
installation .