3.2 BOILER FIXING
To fit the burner to the boiler it is necessary to carry out the following:
Widen, if necessary, the insulating gasket holes (3, fig. 3).
Fix the flange (5) to the boiler door (1) using four screws (4) and (if necessary) the nuts (2) interposing
the insulating gasket (3) but keep unloosing one of the two upper screws (4) (see fig. 2).
Put on the flange (5) the burner combustion head, tighten the flange with the screws (6) and lock the
loose screw (4).
N.B.: The burner can be fixed with the variable dimension (A) (see fig. 4). Anyway, make sure that the
combustion head crosses completely the boiler door thickness.
Fig. 2
3.3
PROBE-ELECTRODE POSITIONING
ATTENTION
Ensure that the plate (3, fig. 5) is always
inserted in the flattening of the electrode.
Lean the probe insulator (4) against the cup (2).
TYPE
911T1
912T1
A
17
20017630
S7002
30
TYPE
A

911 T1
166
70

912 T1
180
170
3.5
±
0.3
3
6
GB
Fig. 3
D5012
A
Fig. 4
D5011
Fig. 5
2
A
±
0.3
1
D6088
4