Programming for FABRIC FALLS INWARD
1. UP/DOWN wiring connection to the switch
MOTOR ON THE RIGHT
SEEN FROM THE INSIDE
2. Setting the UP limit
2.1
CASE A
Press UP until the
limit is reached
CASE B
3. Setting the DOWN limit
3.1
CASE A
Press DOWN until
the limit is reached
CASE B
www.neroxdomo.com
Black: Up
Brown: Down
2.2A
X
Z
Press DOWN until
Current UP
reach the required
limit (X) is ABOVE
position (Z)
the required
position (Z)
2.2B
Z
X
Turn lower knob
Current UP
ANTICLOCKWISE
limit (X) is BELOW
(- to +) until reach
the required
the required
position (Z)
position (Z)
3.2A
Z
X
Press UP until
reach the required
position (Z)
3.2B
X
Z
Turn upper knob
Current DOWN
ANTICLOCKWISE
limit (X) is ABOVE
(- to +) until reach
the required
the required
position (Z)
position (Z)
ECO
2.3A
2.4A
Turn lower knob
Press UP
CLOCKWISE
- If motor moves go
(+ to -) 5 turns
back to step 2.2A
- If it does not
continue to step
2.5A
2.3B
UP limit set
3.3A
3.4A
Turn upper knob
Press DOWN
CLOCKWISE
- If motor moves go
(+ to -) 5 turns
back to step 3.2A
- If it does not
continue to step
3.5A
3.3B
DOWN limit set
8 13
/
35 &
ECO
45
installation manual
MOTOR ON THE LEFT
SEEN FROM THE INSIDE
Brown: Up
Black: Down
2.5A
2.6A
Turn lower knob
UP limit set
ANTICLOCKWISE
(- to +) until reach
the required
position (Z)
3.5A
3.6A
Turn upper knob
DOWN limit set
ANTICLOCKWISE
(- to +) until reach
the required
position (Z)
5 YEARS WARRANTY
ENG