Installed Wall Hangers
Wall
Strainer
Wall Hangers
2. Install the Urinal
For Retrofit Installations
NOTE: The lip height of the urinal will be 6" (15.2 cm) above the
center of the outlet location. If this lip height is not acceptable,
relocate the outlet to achieve an acceptable lip height. The existing
collar may be used with the bracket.
For New Installations
Install the hangers at the vertical dimension above the outlet hole
shown on the roughing-in illustration.
Apply thread sealant tape to the pipe threads on the drain and
install the collar to the drain.
For All Installations
Reference the installation template and position each wall hanger
at the vertical dimension above the outlet hole shown on the
template. To allow for vertical adjustment, place initial screws
through the center of the slots on the wall hangers.
Apply thread sealant tape to the threads on the waste pipe, then
and install the collar to the waste pipe.
Center the bracket on top of the collar. Secure two screws through
the slots on the bracket and into the threaded holes on the collar.
With the beveled surface of the gasket facing away from the
collar, seat the gasket firmly against the collar.
1048746-2-B
All manuals and user guides at all-guides.com
Apply sealant
tape.
Bracket
Washer
Bolt
Screw
Gasket
4
Waste
Pipe
Collar