WIRING INSTRUCTIONS
For Model 653560
1. Open the compartment.
2. Connect the live wires to L1 and L2 of the
terminal block. Connect ground wire to
L1: White live wire L2: Black live wire
FOR 3 PHASE MODELS:
Models 653561 653562 246067
1. Open the wiring cover.
2. Connect the red live wire to L1, black live wire
to L2 and white live wire to L3 of the connector.
Connect ground wire to
L1: Red live wire L2: Black live wire L3: White live wire
TROUBLESHOOTING
If your heater fails to operate, please follow these procedures:
This is a cart stand or wall-mounted heater. It has thermal
cut-off protection. If the thermal cut-off protection trips:
Turn off the power. Turn off the circuit breaker. The unit
Problem
Overheat protection has temporarily
deactivated the heater.
Unit is not
Breaker/Fuse has been tripped.
heating.
Verify that there are no combustible
materials within 0.9 meters (3 feet)
surrounding the heater.
There is oil residue on the heating coil
The heater is
from the manufacturing process. It will
producing
evaporate quickly and should not occur
a burning smell.
again.
Ensure a minimum clearance of 4.5 inches
(11.5 cm) from heater to adjacent walls.
PLEASE DO NOT ATTEMPT TO OPEN OR REPAIR THE HEATER YOURSELF.
DOING SO COULD CAUSE DAMAGE OR PERSONAL INJURY.
All manuals and user guides at all-guides.com
Electric Blower Heater
.
.
Probable Cause
L2
L1
3. Close compartment.
Note: Use wire terminal crimp when connecting
to terminals.
L3
L1
L2
L1
L3
Ground wire
3. Close compartment.
should reset automatically after 10 minutes. If the thermal
cut-off protection trips again, consult a certified electrician
to determine the reason for overheating.
Turn the heater OFF; Switch off the circuit
breaker. Wait 10 minutes before restarting unit.
Check electrical box to confirm the breaker
has not been blown. This may occur if the
receptacle is shared between other high
consumption appliances.
Remove any combustible items near unit.
Ensure heater location is well ventilated.
Reposition heater to increase distance from
adjacent walls.
8
Assembly Instructions
Solution