Clock - Setting of date
Clock - Setting of month
Clock - Setting of year
Miscellaneous
Delay of output signals after start-up
Input signal on DI1. Function:
0=not used. 1=status on DI1. 2=door function with alarm when open. 3=door alarm
when open. 4=defrost start (pulse-pressure). 5=ext.main switch. 6=night operation
7=change reference (activate r40). 8=alarm function when closed. 9=alarm function
when open. 10=case cleaning (pulse pressure). 11=Inject off when open.
Network address
On/Off switch (Service Pin message)
Access code 1 (all settings)
Used sensor type (Pt /PTC/NTC)
Display step = 0.5 (normal 0.1 at Pt sensor)
Max hold time after coordinated defrost
Configuration of light function (relay 4)
1=ON during day operation. 2=ON / OFF via data communication. 3=ON follows the DI-
function, when DI is selected to door function or to door alarm
Activation of light relay (only if o38=2)
Case cleaning. 0=no case cleaning. 1=Fans only. 2=All output Off.
Access code 2 (partly access)
Save the controllers present settings to the programming key. Select your own number.
Load a set of settings from the programming key (previously saved via o65 function)
Replace the controllers factory settings with the present settings
Select application for S5 sensor (0=defrost sensor, 1= product sensor, 2=condenser sen-
sor with alarm)
Select application for relay 4: 1=defrost/light, 2= alarm
Service
Temperature measured with S5 sensor
Status on DI1 input. on/1=closed
Status on night operation (on or off ) 1=closed
Read the present regulation reference
Status on relay for cooling (Can be controlled manually, but only when r12=-1)
Status on relay for fans (Can be controlled manually, but only when r12=-1)
Status on relay for defrost. (Can be controlled manually, but only when r12=-1)
Temperature measured with Sair sensor
Status on relay 4 (alarm, defrost, light).(Can be controlled manually, but only when
r12=-1)
Factory setting
If you need to return to the factory-set values, it can be done in this way:
- Cut out the supply voltage to the controller
- Keep upper and lower button depressed at the same time as you recon nect the supply voltage
Fault code display
E1
Fault in controller
E6
Change battery + check clock
E 27
S5 sensor error
E 29
Sair sensor error
6
Alarm code display
A 1
High temperature alarm
A 2
Low temperature alarm
A 4
Door alarm
A 5
Max. Hold time
A 15
DI 1 alarm
A 45
Standby mode
A 59
Case cleaning
A 61
Condenser alarm
Instructions RI8JV753 © Danfoss 07/2010
t45
t46
t47
o01
o02
o03
o04
o05
o06
o15
o16
o38
o39
o46
o64
o65
o66
o67
o70
o72
defrost /
Light /
Alarm
Alarm
u09
u10
u13
u28
u58
u59
u60
u69
u71
Status code display
S0
Regulating
S1
Waiting for end of the coordinated defrost
S2
ON-time Compressor
S3
OFF-time Compressor
S4
Drip-off time
S10
Refrigeration stopped by main switch
S11
Refrigeration stopped by thermostat
S14
Defrost sequence. Defrosting
S15
Defrost sequence. Fan delay
S16
Refrigeration stopped because of open DI
input
S17
Door open (open DI input)
S20
Emergency cooling
S25
Manual control of outputs
S29
Case cleaning
S32
Delay of output at start-up
non
The defrost temperature cannot be dis-
played. There is stop based on time
-d-
Defrost in progress / First cooling after
defrost
PS
Password required. Set password
1
31
1
1
12
1
0
99
0
0 s
600 s
5 s
0
11
0
0
119
0
OFF
ON
OFF
0
100
0
Pt
ntc
Pt
no
yes
no
0 min
60 min
20
1
3
1
OFF
ON
OFF
0
2
0
0
100
0
0
25
0
0
25
0
OFF
On
OFF
0
2
0
1
2
2
EKC 202A, B, C