PROBLEM
Motor will not
run.
AIR COMPRESSOR REPAIR PARTS
For Parts, Service, Warranty or other Assistance, please call 1-866-422-4286.
CAUSE
Motor overheated
Fuse blown, circuit breaker
tripped.
Extension cord is wrong
length or gauge.
Faulty motor.
Allow compressor to cool for
approximately 30 minutes so
thermal overload switch will
reset. If unit still does not
start, empty air from tank and
refer to "Thermal overload
protector cuts out
repeatedly" information.
Check fuse box for blown
fuse and replace as
necessary. Reset circuit
breaker. Do not use a fuse or
circuit breaker with higher
rating than that specified for
your particular branch circuit.
Check for proper fuse. You
should use a time delay fuse.
Check for low voltage
problem.
Check the extension cord.
Disconnect the other
electrical appliances from
circuit or operate the
compressor on its own
branch circuit.
Check the extension cord.
Have checked by a Trained
Service Technician.
17- ENG
CORRECTION