b) Setting up and mounting
The thermo-/hygrometer can be set up on a horizontal, stable, sufficiently large
surface using the fold-out stand (9). A suitable mat should be used to prevent scratch
marks on valuable furniture surfaces. The stand is also used to protect the LCD. Fold
out the stand to the rear for set-up.
Please note that the weather forecast is not displayed accurately in all
cases.
Setting
The time, date and alarm function can be set.
In setting mode, if you do not press a button for 8 seconds during a setting,
you will exit setting mode and the currently displayed value is saved.
a) Time setting
1. Keep the MODE/SET button (12) pressed until the hour digits flash.
2. Press the UP button (13) or DOWN button (14) to change the hour setting.
3. Press the MODE/SET button to confirm the setting. The minute digits flash.
4. Press the UP button or DOWN, button to change the minute setting.
5. Press the MODE/SET button to confirm the setting.
It is not necessary to set the seconds; they are automatically reset to 00
(zero) each time the hours and minutes are set.
b) Date setting
1. Briefly press the MODE/SET button (12) once to change to date mode. The currently
displayed date is displayed; the M and D symbols appear on the display.
2. Keep the MODE/SET button pressed until the year digits flash.
3. Press the UP button (13) or the DOWN button (14) to change the year digits.
4. Press the MODE/SET button to confirm the setting. The month digits flash.
5. Press the UP button or DOWN button to change the month setting.
6. Press the MODE/SET button to confirm the setting. The number of the date of the
day flashes.
7. Press the UP button or DOWN button to change the day setting.
8. Press the MODE/SET button to confirm the setting.
c) Alarm setting
1. Briefly press the MODE/SET button (12) once to change to alarm mode. The
currently set alarm time is displayed; the wake-up alarm symbol
2. Keep the MODE/SET button pressed until the hour digits of the alarm time flash.
3. Press the UP button (13) or DOWN button (14) to change the hour setting.
4. Press the MODE/SET button to confirm the setting. The minute digits flash.
5. Press the UP button or DOWN, button to change the minute setting of the alarm
time.
6. Press the MODE/SET button to confirm the setting.
Operation
a) Back-lighting of the display
1. Press the SNOOZE/LIGHT button (11) to light up the LCD for 5 seconds.
b) Selecting the temperature unit
1. Press the DOWN button (14) to change the unit of measurement of the temperature
display. Celsius or Fahrenheit is possible (°C, °F).
c) Alarm signal, snooze mode
If the wake-up signal is triggered at the set time, the wake-up alarm symbol
on the LCD. The wake-up signal sounds for 2 minutes. The acoustic wake-up signal
starts with slow tones that become faster - the crescendo alarm. It can be interrupted
at any time (snooze function).
1. Press the UP button (13) to activate the alarm with the set alarm time. The wake-up
alarm symbol
is displayed on the LCD.
2. Press the SNOOZE/LIGHT button (11) or SNOOZE (16) button to interrupt the alarm
for 8 minutes (snooze function).
3. Press any other button to end the wake-up signal.
d) Maximum/minimum measured values
1. Press the MAX/MIN button (15) to display the saved maximum values of
temperature and humidity.
2. Press the MAX/MIN button twice to display the minimum values.
3. Press the MAX/MIN button three times to return to the normal display.
The saved maximum/minimum values of temperature and humidity are reset
to zero at 00:00 (midnight).
All manuals and user guides at all-guides.com
e) 12/24 hours
The display of the time can be selected for the 12 hour format or the 24 hour format.
1. Keep the UP button (13) pressed for 2 seconds to change the display format of the
Maintenance and cleaning
• The product does not require maintenance except for occasional cleaning. For
• Do not use abrasive or chemical cleaning agents.
• Do not immerse the product in water.
Disposal
a) Product
b) (Rechargeable) batteries
You as the end user are required by law (Battery Ordinance) to return all used batteries/
rechargeable batteries. Disposing of them in the household waste is prohibited.
Technical data
Supply voltage .....................................2 x 1.5 V/DC batteries, type AAA
Battery service life..............................approx. 12 months
appears.
Temperature display range ...............-10 to +60 °C
Humidity display range.......................20 - 90% RH
Operating conditions ..........................0 to +50 °C, 20 - 90 % RH
Storage conditions..............................0 to +50 °C, 20 - 90 % RH
Measurements (W x H x D) ...............82 x 31 x 96 mm
Weight ...................................................120 g (without batteries)
flashes
time. The 24 hour format is the default setting. The
cycle of the 12 hour format.
cleaning, use a soft, anti-static and lint-free cloth.
Electronic devices are recyclable waste and must not be disposed of in the
household waste.
At the end of its service life, dispose of the product according to the
relevant statutory regulations.
Remove any inserted (rechargeable) batteries and dispose of them
separately from the product.
Contaminated (rechargeable) batteries are labelled with this symbol to
indicate that disposal in the domestic waste is forbidden. The designations
for the heavy metals involved are: Cd = Cadmium, Hg = Mercury, Pb = Lead
(name on (rechargeable) batteries, e.g. below the trash icon on the left).
Used (rechargeable) batteries can be returned to collection points in your
municipality, our stores or wherever (rechargeable) batteries are sold.
You thus fulfil your statutory obligations and contribute to the protection of
the environment.
This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in electronic data
processing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited. This publication represent the
technical status at the time of printing.
© Copyright 2014 by Conrad Electronic SE.
symbol appears in the second
V1_0714_02-DS