ARF868 Radio Modems- Guide utilisateur / User guide version V2.2.3
1.8. Service interface
The Modem is fitted with 2 push buttons (1 & 2) on its rear face enabling the base settings to be restored in the event of troubleshooting diag-
nostics. The two-colour indicator light on the front face completes this HMI.
Fonction
Button
Modem reset
BP2
Return to
FACTORY serial
BP1
link parame-
ters
Forcing of the
AUTO serial
BP1
link parame-
ters
Entry into the
Command
BP2 and BP1
mode
Restarting of
the modem
BP2 and BP1
with its de-
fault settings
1.9. Mechanical installation - Optimizing performance
1.9.1 Dimensions
Sequence
Press BP2 then
release
Long pressure on
BP1 superior to 3
seconds
Brief pressure on BP1
inferior to 3 seconds
1
2
Press BP2 and
Press BP1 and hold
hold
3
4
Hold BP1 less than 3
Release BP2
sec then release
1
2
Press BP2 and
Press BP1 and hold
hold
3
4
Hold BP1 more than
Release BP2
3 sec then release
135mm
75mm
Action
Pressing BP2 resets the Modem. Hence the equipment
restarts with the parameters in its permanent memory, as
they were configured at the last AT&W command (see § 5
Command mode).
Long pressure on BP1 (> 3s) enables forcing of the serial
link parameters to: RS232, 9600bauds, 8 bits, no parity, no
data rate control. This action will be confirmed by 3 flashes
of the green indicator light.
Brief pressure on PB1 (< 3s) enables restoration of the seri-
al link default settings (interface self-detection, Autobaud, 8
bit data, no parity, no data rate control). This action will be
confirmed by 3 flashes of the green indicator light.
Holding down BP1 (<3s) after having released BP2 triggers
entry into the Command mode. This action will be con-
firmed by 3 flashes of the red indicator light.
Holding down BP1 (>3s) after having released BP2 triggers
restarting of the modem with all the default settings (facto-
ry settings). This action will be confirmed by 3 flashes of the
red indicator light.