• The room thermostat should be lo-
cated where the air temperature can
be sensed as accurately as possible,
without getting adversely aff ected by
direct solar radiation or other heat or
refrigeration sources.
• FIf there are thermostatic radiator
valves in the reference room, set them
to their fully open position.
• Mounting height is about 1.5 m above
the fl oor. The unit can be fi tted to most
commercially available recessed con-
duit boxes or directly on the wall
Mounting and Pedestal
• NOTE: If you want to use the unit free-standing, fasten the pedestal at the back of the controller.
• For wall mounting, fi rst the wall bracket should be mounted on the wall, then the control unit and
the wall bracket must be fi tted as shown in the following fi gure below.
Mounting with Conduit Boxes
WARNING
Risk of electric shock! Only authorized personnel may open the unit to perform service. The
unit must be isolated from the mains supply before opening.
• When installing the unit, fi x the base plate fi rst, then hook on the thermostat body and make the
electrical connections. Then fi t the cover and secure it (
The thermostat and the receiver have a binary code with which the two fa-
cilities can be linked. The link between the thermostat and the receiver usually
has been activated. Please operate according to the following steps in case you
found the link not activated.
1 Plug-in the receiver, the power indicator on the receiver will light. Then press
"study" button and the "Set" indicator will start to fl ashing.
2 Power off the thermostat, press
button again until the "Set" indicator on the receiver stop fl ashing to fi nish
the study.
3 When temp set is higher than room temp, heating icon appear, and receiver
run.
All manuals and user guides at all-guides.com
Mounting Instructions
Linking the Receiver
button for 3 seconds, wait and press the