IRIS2 - User manual
IRIS2 - User manual
BURGLARY CENTRAL
BURGLARY CENTRAL
UNITS
UNITS
In series
to the line
24h
Feeding 12Vdc
Feeding 12Vdc
OPERATION
OPERATION
EMPLOYMENT
EMPLOYMENT
Applying voltage to the detector, the RED LED starts flashing for a minute to allow the stabilization of the infrared sensor
Applying voltage to the detector, the RED LED starts flashing for a minute to allow the stabilization of the infrared sensor
This function prevents to put the sensor out of use masking only one of the two technologies of movement detection and protects the detector by possible housebreaking.
This function prevents to put the sensor out of use masking only one of the two technologies of movement detection and protects the detector by possible housebreaking.
IMPULSE-COUNTER
IMPULSE-COUNTER
If the number of impulses is programmed to one, the detector enables immediately also the OUT output (contacts opening)
If the number of impulses is programmed to one, the detector enables immediately also the OUT output (contacts opening)
and signals the detection also to the antitheft control station
and signals the detection also to the antitheft control station
If the number of programmed impulses is greater than one, the red LED signals with a flash the first detection then remains interdicted for approx two seconds.
If the number of programmed impulses is greater than one, the red LED signals with a flash the first detection then remains interdicted for approx two seconds.
If the movement detection status persists or a new one occurs within the subsequent 15 seconds the red LED repeats the signalling.
If the movement detection status persists or a new one occurs within the subsequent 15 seconds the red LED repeats the signalling.
Every flash by the RED LED (it means every Microwave + PIR detection, only Microwave or only PIR) is counted. When the level set on the impulse-counter is exceeded
Every flash by the RED LED (it means every Microwave + PIR detection, only Microwave or only PIR) is counted. When the level set on the impulse-counter is exceeded
the RED LED turns on and the relay excites generating the alarm.
the RED LED turns on and the relay excites generating the alarm.
NOTE: After 15 seconds from a detection, the impulse counter resets.
NOTE: After 15 seconds from a detection, the impulse counter resets.
When the number of impulse signalling achieves the programmed number, the red LED turns on with fixed light and the OUT contact is open to signal the
When the number of impulse signalling achieves the programmed number, the red LED turns on with fixed light and the OUT contact is open to signal the
alarm to the antitheft control station.
alarm to the antitheft control station.
SWITCH1/SWITCH2 To position the dip-switch according to the wished value:
SWITCH1/SWITCH2 To position the dip-switch according to the wished value:
NOTE: After 15 seconds from a detection, the impulse counter resets.
NOTE: After 15 seconds from a detection, the impulse counter resets.
SIGNALLING LED EXCLUSION
SIGNALLING LED EXCLUSION
Turning the dip switch 4 on ON (SW=ON) the detection and alarm signals of the LEDs are disabled. The only signalling still active are the initial flashing in the detector
Turning the dip switch 4 on ON (SW=ON) the detection and alarm signals of the LEDs are disabled. The only signalling still active are the initial flashing in the detector
turn-on phase and the flashing for the memory input activation.
turn-on phase and the flashing for the memory input activation.
ALARM MEMORY
ALARM MEMORY
This function allows to identify which detector has generated an alarm.
This function allows to identify which detector has generated an alarm.
To enable the alarm memory, connect the input "M" to the output "+INT" of the antitheft control station.
To enable the alarm memory, connect the input "M" to the output "+INT" of the antitheft control station.
Red LED operation (alarm memory)
Red LED operation (alarm memory)
Slow flashing (5 sec.): insertion.
Slow flashing (5 sec.): insertion.
Quick flashing: signalling of the sensor detection with active alarm memory.
Quick flashing: signalling of the sensor detection with active alarm memory.
Acceso fisso: Fixed light: signalling of the sensor detection without active alarm memory.
Acceso fisso: Fixed light: signalling of the sensor detection without active alarm memory.
NOTE The alarm memory cancellation occurs automatically after 5 seconds from the system insertion. The activation occurs after 15 seconds of delay from the system
NOTE The alarm memory cancellation occurs automatically after 5 seconds from the system insertion. The activation occurs after 15 seconds of delay from the system
:
:
insertion.
insertion.
4
All manuals and user guides at all-guides.com
In series to
other contacts or
detectors NC
ON
ON
ON
ON
1 Impulses
1 Impulses
2 Impulses
2 Impulses
SW1=OFF
SW1=OFF
SW1=OFF
SW1=OFF
SW2=OFF
SW2=OFF
SW2=ON
SW2=ON
ON
ON
SW4=ON
SW4=ON
(activated exclusion)
(activated exclusion)
IRIS2
IRIS2
Activation Memory Alarm
ON
ON
ON
ON
3 Impulses
3 Impulses
4 Impulses
4 Impulses
SW1=ON
SW1=ON
SW1=ON
SW1=ON
SW2=OFF
SW2=OFF
SW2=ON
SW2=ON
ON
ON
SW4=OFF
SW4=OFF
(disactivated exclusion
(disactivated exclusion
Regulation sensibility
+