The RL-590 lantern can also be positioned vertically on a table,
floor, any flat horizontal surface using the folding base (11)
and the additional supports for vertical installation (12).
Potential problems and troubleshooting:
Problem
Probable cause
The safety fuse is
Emergency lighting
damaged (for RL-
does not switch on
595 model).
in case of power
The rechargeable
supply cut-off.
battery is not
charged.
The lantern does
The rope switch is
not give light.
not switched on.
The lamp flashes
The lamp is
when being.
damaged.
switched on
The time of con-
The rechargeable
tinuous work is less
battery is not
than 4 hours.
charged.
The rechargeable
battery is damaged.
CARE AND CLEANING
1. Always turn off the appliance and pull the
plug of the cord from the electric wall outlet
before cleaning.
2. Wipe the body of the lantern with a damp
cloth. Do not use the appliance till it becomes
completely dry. Do not use alcohol, gasoline or
any other similar substance for cleaning the ap-
pliance. Also abrasive cleaning materials should
not be used.
3. When you stop using the appliance, wait until it gets cool and
put the cable into the cable storage compartment.
4. The storage temperature of the appliance: from 10 to 40
Any other maintenance operations should be carried out in an
authorized service center.
Do not remove the appliance for storage if it is hot or con-
nected with the electric mains. If the appliance is not used place it
in a box after it is cool completely, and store it in a safe dry place
out of reach of children. Make sure that the appliance and its cord
do not touch sharp edges and are not pressed by heavy objects.
Corrective action
Replace the safety
fuse.
Charge the battery
for 24 hours.
Switch on the rope
switch.
Replace the lamp.
Charge the battery.
Replace the battery
in an authorized
service facility.
o
C.
8