GB
16
Installation distances
C596T
WHEN INSTALLING TURNTABLE (OPTION)
the following installation distances do not apply.
See the separate turntable installation instructions.
Combustible roof
542
INSTALLATION AGAINST COMBUSTIBLE WALLS
Permitted area for
combustible parts
of the building
400
479
* If the stove is placed on a hearth plate made of glass for example (accessory), the height from the floor is affected by a distance corresponding to the thickness of the hearth plate, for a free standing
glass hearth plate this is 10 mm.
** To prevent discolouration of painted non-flammable walls we recommend that the same side distance as to combustible walls is used.
100
400
Combustible wall
717
Combustible wall
750
The minimum distance in front of the
stove opening to combustible parts
of the building or interior decoration
!
must be at least 1 m.
A separate glass hearth plate
The dimension diagrams only show
(accessory) increases the
the minimum permitted installation
connection height to the
distances for the stove. When con-
chimney by 10 mm.
necting to a steel flue, also note the
safety distance requirements of the
flue. The safety distance between an
uninsulated flue and a combustible
part of the building should be at least
463
450 mm.
141
A = height from floor to chimney
Ø150
connection upwards
B = height from floor to c/c chimney
connection rear
C = height from floor to air inlet
32
D = height from floor to lower edge of
hatch
E = minimum height to sloped ceiling
from the centre of the chimney
Air inlet Ø67
100
INSTALLATION AGAINST FIREWALLS
800
Fire-retardant wall of
brick or concrete
592
850
Fire-retardant wall of
brick or concrete
179**
450**