First check the following before submitting the air conditioner for repair.
Problem
The appliance does not switch
on when pressing the on/off key.
The appliance does not cool sufficiently.
The appliance makes a lot of noise.
The appliance does not respond to the remote control
The appliance does not switch on for a period of 3 minutes
after it has been switched on.
Error code P1
Error code E0 EEPROM
Error code E1
Error code E2
Error code E3
Error code E4
Type number
Voltage
Connected load
Cooling capacity*
EE Class*
EER*
Power consumption kW
Power consumption Standby W
Current consumption nom. A
Air displacement max. m
/h
3
Dehumidification max. ** L/h
Suitable for m
3
Refrigerant / GWP type/gr
Thermostat range °C
Fan speeds
Max. noise level dB(A)
Dimensions (hxwxd)
Nett weight
Protection class
Remote control
This symbol means that this product should not be disposed of with regular household waste (2012/19/EU). Observe the rules that apply in your country for the separated
collection of electric and electronic products. Correct disposal of the product prevents negative consequences for the environment and for public health. The packaging
material of this product can be recycled 100%, return packaging material separately.
PROBLEMS AND SOLUTIONS
Possible cause
The indicator light on the water tank flashes and the water
tank is full.
The room temperature is lower
than the set temperature.
Not all doors and windows are closed.
There are heat sources that are active in the room.
The temperature is set too high.
The air inlet is blocked.
The surface on which the appliance is placed is not level of
flat enough.
The noise is caused by the flowing refrigerant liquid within
the air conditioner.
The appliance has been switched on via the control panel
on the appliance itself.
The remote control has not been activated.
The internal safety system of the compressor prevents the
appliance from being switched on until 3 minutes have
passed since it was switched off.
The water tank is full.
Technical defect
Sensor for room temperature defective.
Evaporator sensor defective.
Condenser sensor defective.
Operating panel defective.
TECHNICAL SPECIFICATIONS
TMA7000B
220-240Volt ~50Hz
980 Watt
7000Btu/h (2.0kW)
A
2.6
0,8
0,5
3.45
272
1,94
60
R-290 / 3 /140 g.
17 - 30
2
62 dB(A)
634 x 329 x 318 mm
21.5 kg
IPX0
yes
RECYCLING
EN - 24
Solution
Empty the water tank.
Set the temperature once more.
Make sure that all doors and windows are closed.
Remove the heat sources or switch them off if possible.
Set the temperature once more.
Clean the air inlet grille.
Place the appliance on a flat surface, level if possible.
This is normal.
Press the on/off button on the remote control to activate it.
This delay is normal and the appliance will function normally
after the 3 minutes have passed
Empty the water tank.
Contact the Tomado service department.
Contact the Tomado service department.
Contact the Tomado service department.
Contact the Tomado service department.
Contact the Tomado service department.

Publicité