CLEANING THE GENERATOR
Generator maintenance consists of keeping the
unit clean and dry. Be sure to store the unit in a
clean and dry environment, where it will not be
exposed to excessive dust, dirt, moisture or any
corrosive vapors. Cooling slots should always
be clean and free from clogs.
Note: Do not use a garden hose to clean the
generator. Water can enter the fuel and intake
system and cause problems. In addition, if water
and dirt buildup on the generators internal
windings, the resistance of these windings will
decrease.
•
To clean the generator, use a damp cloth to
wipe the exterior surfaces.
•
Use a soft bristle brush to loosen caked on
dirt of oil.
•
Use a vacuum cleaner to pick up loose dirt
and debris.
•
Compressed air (not to exceed 25 psi) may
be used to blow away dirt.
SPARK PLUG
•
Remove the spark plug
•
Remove the carbon deposits
•
Check for discoloration. Standard is tan in
color.
•
Check spark plug gap
Tele: (888)908-6200
0.7~0.8 mm (.028~.031 inches)
NOTE: If spark plug needs to be replaced, use
NGK(or LG) Brand: BPR4ES or F6(R)TC