Télécharger Imprimer la page

Viking Range VIPR102 Mode D'emploi page 7

Publicité

Les langues disponibles

Les langues disponibles

VIKING RANGE CORPORATION
MOUNT THE UNIT
All Units
1. Set downdraft into opening. Extend leveling brackets to floor
of cabinet so downdraft sits straight. (Note: Leveling brackets
can be removed and re-attached in other positions. Bottom
flange may have to face inward in tight cabinet installations.)
2. Secure the downdraft to the countertop as follows: Hold the
downdraft against the back of countertop cut-out and tighten-
ing the two mounting screws (one on each end of unit) on
underside of countertop. Use a wood shim between screw
and underside of granite countertops.
3. Screw leveling brackets to bottom of cabinet. Tighten screws
holding leveling bracket to unit on each side.
INSTALL DUCTWORK
Interior Blower Installation
 BLOWER 
COLLAR
SCREWS
1. Cut hole in cabinet as well as holes in wall or floor as necessary.
2. Mount the roof or wall cap and work back towards the cabinet,
attaching all ductwork, elbows and transitions as previously
planned. Tape all ductwork connections to make them secure
and air tight.
3. Connect ductwork (and transition, if required) to downdraft.
If necessary, LOOSEN nuts and screws that hold the blower
in place, and slide blower left or right to meet ductwork.
Re-tighten screws and nuts.
Note: A 3-1/4" x 10" collar is provided for installers who prefer to
rivet the ductwork to the unit. This will allow blower to be removed and
replaced easily in service situations without disturbing ductwork.
LEVELING BRACKET -
FLANGE FACING OUT
LEVELING BRACKET -
FLANGE FACING IN
!
CAUTION:
BEFORE CUTTING HOLE IN
CABINET FOR DUCTWORK,
check for interference with floor
joists, wall studs, electrical
wiring, or plumbing.
3-1/4" X 10"
TO 6" RD.
TRANSITION
6" RD. ELBOW
& DUCTWORK
1. Cut hole in cabinet as well as holes in wall or floor as necessary.
2. Mount the exterior blower and work back towards the cabinet,
3. Connect ductwork to downdraft. If necessary, LOOSEN nuts
7
Downdraft Ventilators
MOUNTING SCREWS
Exterior Blower Installation
ELBOW
10" ROUND DUCT
attaching all ductwork, elbows and transitions as previously
planned. Tape all ductwork connections to make them secure
and air tight.
and screws that hold remote blower adapter plate in place,
and slide outlet assembly left or right to meet ductwork.
Re-tighten screws and nuts.
ELBOW

Publicité

loading

Ce manuel est également adapté pour:

Vipr102rVipr162Vipr162rVipr182Vipr182r