Télécharger Imprimer la page

Viking Range VIPR102 Mode D'emploi page 5

Publicité

Les langues disponibles

Les langues disponibles

VIKING RANGE CORPORATION
PLAN THE WIRING
Interior Blower Installation
1. The Interior Downdraft Blower system draws 4 AMPS and
requires a 120 VAC, 60 Hz circuit.
2. The downdraft has a 2 ft. long power cord with a 3-pronged
plug. Plan to provide a grounded outlet in a location which will
allow the unit's power cord to reach.
IMPORTANT - LOCATION OF ELECTRICAL OUTLET:
If Models VIPR102SS or VIPR102RSS are being installed
in a 30" wide cabinet...
or Models VIPR162SS or VIPR162RSS are being
installed in a 36" wide cabinet...
or Models VIPR182SS or VIPR182RSS are being
installed in a 48" wide cabinet...
...the outlet cannot be located on the back wall of
cabinet.
In these cases, the width of the downdraft covers nearly the
entire width of the back wall of the cabinet. So you must
either:
mount the electrical box to a side wall or cabinet floor
- at least 12 inches from the back wall.
mount the electrical box to a wall stud behind the
cabinet - where it will not be covered by the downdraft.
Then provide a clearance hole in the back wall of the
cabinet.
PREPARE THE DOWNDRAFT
Interior Blower Installation
The downdraft is shipped without a blower. Purchase a Model
VIDV500 Interior Blower and mount it to the downdraft as follows:
1. Place the downdraft on its back on a table of flat work surface.
2. Remove the 4 nuts and 2 clamp channels.
3. Remove 2 screws and the gear motor cover.
4. Carefully position the blower under the bottom flange of the
downdraft with the 3¼" x 10" discharge pointed in the desired
direction.
5. Connect motor plug.
6. Replace the gear motor cover and 2 sheet metal screws.
7. Replace the 2 clamp channels and start the 4 nuts, do not
tighten.
8. Slide blower left of right to desired position. Use cover plate
(supplied) to close up any open space.
9. Tighten 4 nuts to secure top of blower. Use additional screws
(supplied) through bottom flange to secure bottom in blower.
Exterior Blower Installation
1. The Exterior Downdraft Blower system draws 6 AMPS and
requires a 120 VAC, 60 Hz circuit.
2. The downdraft has a 2 ft. long power cord with a 3-pronged
plug. Plan to provide a grounded outlet in a location which will
allow the unit's power cord to reach.
IMPORTANT - LOCATION OF ELECTRICAL OUTLET:
If Models VIPR102SS or VIPR102RSS are being installed
in a 30" wide cabinet...
or Models VIPR162SS or VIPR162RSS are being
installed in a 36" wide cabinet...
or Models VIPR182SS or VIPR182RSS are being
installed in a 48" wide cabinet...
...the outlet cannot be located on the back wall of
cabinet.
In these cases, the width of the downdraft covers nearly
the entire width of the back wall of the cabinet. So you must
either:
mount the electrical box to a side wall or cabinet floor
- at least 12 inches from the back wall.
mount the electrical box to a wall stud behind the
cabinet - where it will not be covered by the downdraft.
Then provide a clearance hole in the back wall of the
cabinet.
PLEASE NOTE: External blowers must be hard-wired using
locally-supplied wire and connected to the downdraft plug
(included).
NUTS
CLAMP
CHANNELS
SCREWS
GEARMOTOR
COVER
5
Downdraft Ventilators
3¼" X 10"
DISCHARGE
BLOWER
MOTOR
PLUG
ADDITIONAL
SCREWS
BOTTOM
FLANGE
COVER
PLATE

Publicité

loading

Ce manuel est également adapté pour:

Vipr102rVipr162Vipr162rVipr182Vipr182r