Enabling ACT™
To enable ACT™:
1. Before hood installation, gain access to PC board by following the steps shown on FIG. I.
2. Change plastic jumper positioning as shown in FIG. J to set the desired maximum blower CFM.
3. Re-install PC board and continue with hood installation.
4. Remove the appropriate foil CFM sticker included with the hood literature and place inside the
hood body below the wiring diagram or in another clearly visible location.
To verify if your installer enabled ACT™:
1. With hood off, hold the power button for three seconds. If 5 LEDs illuminate = default max. If 3
LEDS illuminate = max. 290 CFM.
2. When ACT™ is enabled, the number of blower speeds will be reduced. 290 CFM = max. 3 speeds.
3. There should also be a foil label located inside the hood body near the wiring diagram that
indicates the blower CFM.
Model: ZSI
- PC board located behind the light panel.
- Remove baffle filters.
- Remove 2 screws attaching light panel.
FIG. I
Siena Use, Care, and Installation Guide
ACT™ Conversion
7
8
5
6
3
4
1
2
J u m p e r 3 - 4
Max. Blower CFM
PC Board
FIG. J
Jumper Pins
7
8
5
6
3
4
1
2
J u m p e r 5 - 6 or 7-8
DEFAULT POSITION
Default Max. Blower CFM
7
8
7
5
6
5
3
4
3
1
2
1
J u m p e r 1 - 2
Max. Blower CFM
390
Plastic
Jumper
8
6
4
2
290
19