In a dusty environment the AirBox should be mounted with the
filter facing downwards.
Materials
(1) Viton
(2) stainless steel (303 S21)
(2) fixing screws
(2) press-in catridge
Compressed air
Adhere to the safety regulations and provisions for the installation of
pneumatic systems. Switch off pressure.
Connect the compressed air supply 1 (P), the pneumatic output
(NO/NC selectable) 2 and 4 and, if necessary, the exhaust 3 (R) to the
pneumatic system. Cut the connection tube straight and push it into
the tube fitting until you can feel the tube latch.
Removal of the tubes
To remove the tubes, push the black ring and pull out the tube at the
same time.
Manual override
The pneumatic output (NO/NC selectable) can be activated manually
by means of the screw for the manual override (pressing/releasing or
pressing/turning/locking).
2
4
(1) O-ring
(1) profiled seal / flat seal
I-1
I-2
PWR
AUX
O-3
(2) tube connection
(1) O-ring
(2) manual override
(2) cover
7