Page 4
Instruction CF-WR Electronic Wireless Relay 1. Functional overview CF-WR Wireless Relay CF-MC Master Controller PROG button with PROG LED. Menu Selection button. Button not used for CF2 Install LED. OK button. Danfoss Heating Solutions VISPP21C...
Page 5
Instruction CF-WR Electronic Wireless relay 2. Installation Activate CF-MC Master Controller: • Select Install Mode with the Menu Selection button . The Install LED flashes. • Press the OK button to activate Install Mode. The Install LED lights continously.
Page 6
• If installation fails: The PROG LED flashes 5 times. Repeat the installation procedure. 3. Configuration Configuration of CF-WR Wireless Relay is made with the CF-RC Remote Con- troller. Please refer to the instruction for CF-RC for further information. 4. Uninstallation / Factory Reset 1.
Page 7
Instruction CF-WR Electronic Wireless relay 5. Wiring Electronics 1 Not in use 2 Com 3 Zone 1 on 4 Zone 1 off Note: For mains voltage applications link terminals L and 2. 6. Troubleshooting Error indication Possible cause The PROG LED flashes 5 times...
Page 8
Instruction CF-WR Electronic Wireless Relay 7. Specifications Supply voltage 230 Vac ± 15%, 50 Hz Construction EN 60730-1, EN 300-220-1 Max. ambient temperature 45°C Switch type 1 x SPDT, type 1B Switch rating 230 Vac, 12 (6) A IP class...
Page 10
Instruktion Funkgesteuertes Relais CF-WR 2. Installation Aktivieren Sie den CF-MC-Hauptregler: • Wählen Sie den Installationsmodus anhand der Menü-Auswahltaste . Die Installations-LED blinkt. • Drücken Sie die Taste OK, um den Installationsmodus zu aktivieren. Die Installations-LED leuchtet dauerhaft.
Page 11
• Installation fehlgeschlagen: die LED PROG blinkt 5 mal. Wiederholen Sie das Installationsverfahren. 3. Konfiguration Die Konfiguration des funkgesteuerten Relais CF-WR wird über die Fernbedie- nung des CF-RC vorgenommen. Weitere Informationen entnehmen Sie der Anleitung des CF-RC. 4. Deinstallation / Rücksetzen auf Werkseinstellungen 1.
Page 12
Instruktion Funkgesteuertes Relais CF-WR 5. Verkabelung Elektronik 1 Nicht in Gebrauch 2 Com 3 Zone 1 ein 4 Zone 1 aus Anmerkung: für Netzspannungsanwendungen, die Klemmen L und 2 verbinden. 6. Fehlersuche Fehleranzeige Mögliche Ursache Die LED PROG blinkt 5 mal...
Page 13
Instruktion Funkgesteuertes Relais CF-WR 7. Technische Daten Versorgungsspannung 230 V AC ± 15%, 50 Hz Konstruktion EN 60730-1, EN 300-220-1 Max. Umgebungstemperatur 45°C Schaltertyp 1 x SPDT, Typ 1B Schaltleistung 230 Vac, 12 (6) A IP-Schutzart IP40 Verschmutzungsgrad der RS-Umgebung Grad 2 Max.
Page 16
• Hvis installationen mislykkes: Indikatoren PROG blinker 5 gange. Gentag installationsproceduren. 3. Konfiguration Konfiguration af CF-WR Trådløst relæ foretages med CF-RC-fjernbetjeningen. Se i vejledningen til CF-RC for at få yderligere oplysninger. 4. Afinstallation/fabriksnulstilling 1. Afbryd CF-WR Trådløst relæ fra strømforsyningen.
Page 17
Vejledning CF-WR Elektronisk Trådløst relæ 5. Ledningsføring Elektronik 1 Ikke i brug 2 Com 3 Zone 1 ON 4 Zone 1 OFF Bemærk: I applikationer med netspænding skal klemme L og 2 forbindes. 6. Fejlfinding Fejlmelding Mulig årsag Indikatoren PROG blinker 5 gange...
Page 18
Vejledning CF-WR Elektronisk Trådløst relæ 7. Specifikationer Forsyningsspænding 230 Vac ± 15 %, 50 Hz Konstruktion EN 60730-1, EN 300-220-1 Max. omgivelsestemperatur 45° C Kontakttype 1 x SPDT, type 1B Kontaktbelastning 230 Vac, 12 (6) A IP-klasse IP 40 Forureningskontrolforhold Grad 2 Maks.
Page 20
Instructions Relais sans fil CF-WR 2. Installation Activer le contrôleur central CF-MC : • Sélectionner le mode Installation à l’aide du bouton de sélection des menus . Le voyant Install clignote. • Appuyer sur le bouton OK pour activer le mode Installation. Le voyant Install ...
Page 21
• Si l’installation échoue, le voyant PROG clignote 5 fois. Répéter la procédure d’installation. 3. Configuration La configuration du relais sans fil CF-WR est assurée via la commande à dis- tance CF-RC. Se référer aux instructions du CF-RC pour des informations complémentaires.
Page 22
Instructions Relais sans fil CF-WR 5. Câblage Éléments électroniques 1 Non utilisé 2 Com 3 Zone 1 allumée 4 Zone 1 éteinte Remarque : pour les applications de tension secteur, relier les bornes L et 2. 6. Dépannage Indication d’erreur...
Page 23
Instructions Relais sans fil CF-WR 7. Spécifications Tension d’alimentation 230 V CA ±15 %, 50 Hz Construction EN 60730-1, EN 300-220-1 Température ambiante max. 45 °C Type de commutateur 1 x SPDT, type 1B Régime nominal du commutateur 230 Vac, 12 (6) A...
Page 26
• Om installationen lyckades slocknar PROG-lysdioden. • Om installationen misslyckades blinkar PROG-lysdioden 5 gånger. Upprepa installationsproceduren. 3 Konfiguration Det trådlösa reläet CF-WR konfigureras med hjälp av fjärrkontrollen CF-RC. Mer information finns i bruksanvisningen för CF-RC. 4 Avinstallation/fabriksåterställning 1. Bryt strömmen till det trådlösa reläet CF-WR.
Page 28
Bruksanvisning CF-WR trådlöst relä 7 Specifikationer Matningsspänning 230 V AC ± 15 %, 50 Hz Konstruktionsstandard SS-EN 60730-1, SS-EN 300-220-1 Max. omgivningstemperatur 45 °C Typ av brytare 1 x SPDT, typ 1B Brytarklassificering 230 Vac, 12 (6) A IP-klassificering IP 40 Reglering av föroreningar...
Page 30
Instrukcja obsługi Przekaźnik bezprzewodowy CF-WR 2. Instalacja Aktywacja regulatora nadrzędnego CF-MC • Za pomocą przycisku wyboru menu wybrać tryb instalacji. Miga dioda instalacji . • Nacisnąć przycisk OK , aby włączyć tryb instalacji. Dioda instalacji świeci w sposób ciągły.
Page 31
• W razie niepowodzenia instalacji dioda PROG miga 5 razy. Należy powtórzyć procedurę instalacji. 3. Konfiguracja Przekaźnik bezprzewodowy CF-WR konfiguruje się za pośrednictwem pilota CF-RC. W celu uzyskania dodatkowych informacji należy skorzystać z instrukcji pilota CF-RC. 4. Odinstalowanie / resetowanie do ustawień...
Page 32
Instrukcja obsługi Przekaźnik bezprzewodowy CF-WR 5. Schemat elektryczny Elektronika 1 Nieużywane 2 Zasilanie odbiornika (L) 3 Strefa 1 wł. 4 Strefa 1 wył. Uwaga! W przypadku zastosowań z zasilaniem sieciowym połączyć zaciski L i 2. 6. Usuwanie usterek Wskazanie błędów Możliwa przyczyna...
Page 33
Instrukcja obsługi Przekaźnik bezprzewodowy CF-WR 7. Specyfikacje Napięcie zasilania 230 VAC ± 15%, 50 Hz Budowa EN 60730-1, EN 300-220-1 Maks. temperatura otoczenia 45°C Typ przełącznika 1 x SPDT, typ 1B Obciążalność przełącznika 230 Vac, 12 (6) A Klasa IP IP 40 Klasa czystości pomieszczenia...
Page 35
Handleiding CF-WR Draadloos relais 2. Installatie CF-MC Hoofdregelaar activeren: • Gebruik de menukiezer om de installatiemodus te selecteren. De instal- latieled knippert. • Druk op de OK-knop om de installatiemodus te activeren. De installatieled brandt constant.
Page 36
Lees voor meer informatie de handleiding voor de CF-RC. 4. De-installatie / Reset naar fabrieksinstellingen 1. Koppel het draadloze relais CF-WR los van de voeding. 2. Houd de PROG-knop ingedrukt. 3. Sluit de voeding weer aan terwijl u de PROG-knop ingedrukt houdt.
Page 37
Handleiding CF-WR Draadloos relais 5. Bedrading Elektronica 1 Wordt niet gebruikt 2 Com 3 Zone 1 aan 4 Zone 1 uit NB: Verbind voor netspanningstoepassingen klemmen L en 2. 6. Probleemoplossing Foutmelding Mogelijke oorzaak De PROG-led knippert 5 keer...
Page 38
Handleiding CF-WR Draadloos relais 7. Specificaties Voedingsspanning 230 V AC ±15%, 50 Hz Constructie EN 60730-1, EN 300-220-1 Max. omgevingstemperatuur 45 °C Type schakelaar 1 x SPDT, type 1B Vermogen schakelaar 230 Vac, 12 (6) A IP-klasse IP 40 Emissiewaarde Niveau 2 Max.
Page 40
Istruzioni Relé senza fili CF-WR 2. Installazione Attivazione del regolatore principale CF-MC • Selezionare la modalità d’installazione con il tasto di selezione menu . Il LED d’installazione lampeggia. • Premere il tasto OK per attivare la modalità d’installazione. Il LED d’instal- lazione ...
Page 41
• Se l’installazione non è stata eseguita correttamente: il LED PROG lampeggia per 5 volte. Ripetere la procedura d’installazione. 3. Configurazione Il relé senza fili CF-WR viene configurato attraverso il Regolatore a distanza CF-RC. Per ulteriori informazioni, consultare le istruzioni per CF-RC.
Page 42
Istruzioni Relé senza fili CF-WR 5. Cablaggio Elettronica 1 Non in uso 2 Com 3 Zona 1 on 4 Zona 1 off Nota: per le applicazioni con tensione di rete collegare i morsetti L e 2. 6. Ricerca guasti...
Page 43
Istruzioni Relé senza fili CF-WR 7. Specifiche Tensione di alimentazione 230 V CA ± 15%, 50 Hz Costruzione EN 60730-1, EN 300-220-1 Temperatura ambiente max. 45°C Tipo di interruttore 1 x SPDT, tipo 1B Valore interruttori 230 Vac, 12 (6) A...