Télécharger Imprimer la page

Napoleon ROGUE RXT625SIB Mode D'emploi page 8

Masquer les pouces Voir aussi pour ROGUE RXT625SIB:

Publicité

Les langues disponibles

Les langues disponibles

8
WARNING!
• The installation must be performed by a licensed gas fitter, and all connections must be leak
EN
tested before operating the grill.
• Do not route hose underneath the drip pan.
• Do not route hose between bottom shelf space and back panel.
• Do not route hose over top of rear panel.
• Ensure all hose connections are tightened using two wrenches. Do not use Teflon tape or pipe
dope on any hose connection.
• Ensure the hose does not contact any high temperature surfaces or it may melt and leak causing a
fire.
• Leak test all the connections using a soap and water solution as per the leak testing instructions
found in the manual.
• The outdoor cooking gas appliance and its individual shutoff valve must be disconnected from the
gas supply piping system during any pressure testing of that system at test pressures in excess of
0.5 psi (3.5 kPa).
• The outdoor cooking gas appliance must be isolated from the gas supply piping system by closing
its individual manual shutoff valve during any pressure testing of the gas supply piping system at
test pressures equal to or less than 1/2 psi (3.5 kPa).
Leak Testing Instructions
!
WARNING!
part of the gas system is replaced.
WARNING!
!
are in the area while you check for leaks. Sparks or open flames will result in a fire or explosion,
damage to property, serious bodily injury, or death.
Leak testing: This must be done before initial use, annually, and whenever any gas components are
replaced or serviced. Do not smoke while performing this test, and remove all sources of ignition. See Leak
Testing Diagram for areas to check. Turn all burner controls to the off position. Turn gas supply valve on.
Brush a half-and-half solution of liquid soap and water onto all joints and connections of the regulator,
hose, manifolds and valves.
Bubbles will indicate a gas leak. Either tighten the loose joint or have the part replaced with one
recommended by the Napoleon Customer Solutions department and have the grill inspected by a certified
gas installer.
STOP
If the leak cannot be stopped, immediately shut off the gas supply, disconnect it, and have the grill
inspected by a certified gas installer or dealer. Do not use the grill until the leak has been corrected.
www.napoleon.com
A leak test must be performed annually and each time a cylinder is hooked up or if a
Never use an open flame to check for gas leaks. Be certain no sparks or open flames
N415-0573 JuN 08.20