APPROPRIATE USE
The GAS ALARM GX-C3 with external sensor is a gas warning device for town, natural and
liquefied gases and can already deliver a warning at a gas concentration that lies well below
life-threatening values. This monitoring system is, therefore, in line with its purpose, set to
a very high sensitivity (see table TECHNICAL DATA). The alarm is signalled acoustically/
optically and the connected gas appliance is turned off at the same time. The unit is suitable
for normal household use and may not be used in areas at risk of explosion.
Another use of the device as described above is not authorized.
TECHNICAL SPECIFICATIONS
Operating voltage:
Power consumption:
Switching capacity:
Operating temperature:
Protection type:
Acoustic pressure sounder:
Cable length:
Dimensions (HxWxD):
Data diagram Sensor
Gas type
CO
8
230 (+/-10%) V AC / 50-60 Hz
approx. 1.5 VA
2300 W / 10 A
-15°C / +40°C
IP 20
60 dB @ 10 cm
2.5 m
121x57x38 mm
Trigger point acc. to diagram
200ppm (0.02%)
Minimum concentration
<0.04%