Turning your appliance ON and OFF:
If the appliance is "On", (and out of sleep mode) the tem-
perature will be shown in the display area of the control.
To turn the appliance "Off", press and hold the "On/Off"
keypad for 4-seconds. "OFF" will now be displayed on the
control.
To turn the appliance "On", press and hold the "On/Off"
keypad for 4-seconds.
Adjusting the temperature:
To set or check the set-point temperature (with the control
out of sleep mode), press the "-" or "+" keypads. "SET" will
be indicated on the user interface panel and the current
set-point temperature will display and flash. Subsequent
presses of the "-" or "+" keypads will adjust the temperature
colder or warmer respectively. When you have reached
your desired set-point temperature, press the "On/Off" key-
pad to accept, or do nothing and the "Set" mode will time-
out in 10-seconds accepting the displayed temperature as
the new set-point.
The available set-point temperature range for your appli-
ance is -10°F (-23°C) to 10°F (-12°C). If you attempt to
adjust the temperature outside of this range you will receive
an audible notification.
NOTE
Loading warm contents may trigger a temperature alarm,
see temperature alarm page 13. Depending on the quantity
and/or weight of warm contents, it may take 48 hours for
the compartment temperature to stabilize.
When making temperature set-point changes, it may take
up to 24-hours for the stored contents to stabilize at your
new set-point temperature.
USING YOUR ELECTRONIC CONTROL
Factors that affect the storage compartment stabilized
temperature:
Changes to temperature setting.
Room temperature changes.
Temperature of stored contents.
- Loading warm contents.
- Cold content load will delay the change to a warmer
set-point temperature.
- Warm content load will delay the change to a colder
set-point temperature.
Usage, (number and duration of the door openings).
Use of the storage compartment display lighting, (glass
door product only).
Installation of the appliance in direct sunlight or next to
a heat source.
Temperature mode:
The temperature mode is preset from the factory in Fahren-
heit (°F) but you have the option to change it to Centigrade
(°C). To change the mode, press and hold the "-" keypad,
while pressing the "+" keypad, then release the "-" keypad.
The temperature will now be displayed in Centigrade (°C).
Repeat the procedure to change the temperature mode
back to Fahrenheit (°F).
Control lock:
The control panel can be locked to avoid unintentional
changes. To lock the control, press and hold the "Lock" key-
pad until the display reads "Loc" then immediately release
your finger from the keypad. The lock icon will flash 3-times
and then continuously illuminate. When the control panel is
locked, only the Lock keypad, System Status OK indicator,
and the Alarm indicator are active. To un-lock the control
panel, repeat this instruction until the display reads "nLc"
then immediately release your finger from the keypad.
.
NOTE
If the control lock is active (illuminated lock icon) the
control will have to be unlocked before using the key-
pad to reset an alarm condition. See page 11 (Control
Lock) for instructions for unlocking the control.