Instructions for installation and use
3. Product description
3.1. Scope of delivery
● Sauna control unit
● Heater sensor with integrated excess temperature fuse
● Sensor wires
● Installation material
3.2. Optional accessories
● Bench sensor (item number: O-F2)
● Power booster (item number: O-S2-18 / O-S2-30)
● Safety shut-off (item number: SFE-xxxxx)
● pronet web server (item number: PRO-NET)
3.3. Product functions
The sauna control unit Pro B2 features the following functions:
● Regulation of sauna heaters with a heating output of up to 10.5 kW in the
temperature range spanning 30 °C to 110 °C.
● A power booster allows the maximum contact rating to be increased from
10.5 kW to 18 kW or 30 kW.
● Remote start function
● Preset time function (up to 24 hours)
● Automatic heating period limiter
The sauna control unit shuts down automatically after the maximum heating
period for safety reasons. The maximum heating period can be set to 6 h,
12 h, 18 h or 24 h.
● Excess temperature fuse
The excess temperature fuse is installed in the housing for the heater sen-
sor. Should the sauna heater continue heating after reaching the preferred
temperature due to a defect, the excess temperature fuse switches the sauna
heater off at a temperature of approx. 139 °C.