3.4
Lithiumion battery status display
The charge state of the Li-ion battery and malfunctions of the product are indicated by the indicator of the
Liion battery. The charge status of the Liion battery is indicated after one of the two battery release buttons
is short-pressed.
Status
4 LEDs light.
3 LEDs light.
2 LEDs light.
1 LED lights.
1 LED flashes.
Battery state of charge cannot be displayed while the control switch is pressed and for up to 5 seconds
after releasing the control switch. If the LEDs of the charge state indicator flash, follow the instructions
in the 'Troubleshooting' section.
3.5
Items supplied
Crimping / pressing tool, operating instructions.
Other system products approved for use with this product can be found at your local HILTI STORE or online
at: www.hilti.group
3.6
Selection of the connecting material
A table to assist with selecting the type of cable and cable terminal to be used can be found at the end of
these operating instructions.
4
Technical data
Rated voltage
Weight in accordance with EPTA Procedure 01 including batteryB22⁄8.0
Max. crimping force
Crimping time
Max. permissible crimping capacity
Storage temperature
Ambient temperature for operation
4.1
Noise information and vibration values in accordance with EN 60745
The sound pressure and vibration values given in these instructions were measured in accordance with a
standardized test and can be used to compare one power tool with another. They can also be used for a
preliminary assessment of exposure. The data given represents the main applications of the power tool.
However, if the power tool is used for different applications, with different accessory tools, or is poorly
maintained, the data can vary. This can significantly increase exposure over the total working period. An
accurate estimation of exposure should also take into account the times when the tool is switched off, or
when it is running but not actually being used for a job. This can significantly reduce exposure over the
total working period. Identify additional safety measures to protect the operator from the effects of noise
and/or vibration, for example: Maintaining the power tool and accessory tools, keeping the hands warm,
organization of work patterns.
Noise values
Sound (power) level (L
Uncertainty for the sound power level (K
*2207049*
)
WA
)
WA
2207049
Meaning
State of charge: 75 % to 100 %
State of charge: 50 % to 75 %
State of charge: 25 % to 50 %
State of charge: 10 % to 25 %
State of charge: < 10 %
NCR 060 II-A22
21.6 V
3.3 kg
53 kN
≈ 5 s
•
500 MCM (240
mm²) Cu
•
350 MCM
(240 mm²) Al
−20 ℃ ... 70 ℃
−17 ℃ ... 60 ℃
80 dB(A)
2.5 dB(A)
English
15