OPERATION
 
 
 Plug the power cord into AC power source. 
Caution: Make sure the operating voltage of Eco PowerGuard TVFR is correct before connecting it to 
AC power source. 
The current display panel flashes once and the Surge Protection, Grounding, and Permanently‐On 
LED lights come on. 
Note: For the moment remote‐controlled outlets are still off. 
 
 
  Use  one  of  your  IR  remote  to  turn  on  Eco  PowerGuard  TVFR.  The  current  display  panel  and 
Power LED will be turned on. 
Note:  
1.  Eco  PowerGuard  TVFR  has  a  limited  reception  frequency  range  as  described  in  the  Electrical 
section of the Specifications. Please contact the electrical appliance service agency if your remote 
does not turn on Eco PowerGuard TVFR. 
 
2. Any function key of an IR remote control should enable the Eco PowerGuard TVFR unit. 
 
3. The Eco PowerGuard TVFR product cannot be turned off ‐ the power cord has to be unplugged 
from the AC power source. 
 
4. The IR LED will flash once when the signal is received. 
 
 
  The  remote‐controlled  outlets  supply  now  the  power  to  the  connected  electrical  appliances. 
Turn on the connected electrical appliances. 
Note: The current display will show the total current consumption for all remote‐controlled outlets 
only. 
 
 
 Turn your appliances off with the usual remote control. Eco PowerGuard TVFR will automatically 
detect a variation of the total power consumption. If the total power consumption falls below 70% 
of  the  peak  current  load,  after  3  minutes  Eco  PowerGuard  TVFR  shuts  down  and  switches  to 
standby mode. 
Note: 
  
1. Please see shutdown conditions in the specifications for details. 
2. Only the remote‐controlled outlets will go off (permanently‐on outlets are remain on). 
 
 
  Repeat  Step  3  to  turn  on  the  connected  electrical  appliances  again  once  the  Eco  PowerGuard 
TVFR has switched to standby mode. 
 
 
INFOSEC UPS SYSTEM – 4 rue de la Rigotière – 44700 Orvault – France – www.infosec-ups.com
Hot Line Tel: +33 (0)2 40 76 15 82 – fax: +33(0)2 40 94 29 51 – hotline@infosec.fr – 06 09 AA 08 204 27