Télécharger Imprimer la page

Publicité

Liens rapides

BATH MIXING PROGRAM
PROGRAMME DU MITIGEUR POUR LA SALLE DE BAIN
PROGRAMA MEZCLADORES BAÑO
Art. 59090
Gessi SpA - Parco Gessi
13037 Serravalle Sesia (Vercelli) - Italy
Phone +39 0163 454111 - Facsimile +39 0163 459273
www.gessi.com - gessi@gessi.it

Publicité

loading

Sommaire des Matières pour Gessi Rilievo 59090

  • Page 1 BATH MIXING PROGRAM PROGRAMME DU MITIGEUR POUR LA SALLE DE BAIN PROGRAMA MEZCLADORES BAÑO Art. 59090 Gessi SpA - Parco Gessi 13037 Serravalle Sesia (Vercelli) - Italy Phone +39 0163 454111 - Facsimile +39 0163 459273 www.gessi.com - gessi@gessi.it...
  • Page 2 MUST NEVER BE EXCEEDED, as it may damage and/or cause ruptures and/or leakages and/or even break the product, and present a potential hazard and danger to safety, health and/or property. Following are the technical data with respect to the installation of Gessi plumbing products. ► W orkingpressureshouldnotbelowerthan0,5bar(7,25psi)andnotbehigherthan5bar(72Psi).In case of higher working pressure use a pressure reducer valve.
  • Page 3 Ci-dessous nous indiquons les données techniques concernant l’installation des produits sanitaires Gessi. ► L apressiondeservicenedoitpasêtreinférieureà0,5bar(7,25psi)etsupérieureà5bar(72Psi).En cas de pressions de service plus hautes utiliser une soupape de réduction de la pression.
  • Page 4 1 - ¡CUIDADO!! LES ROGAMOS QUE TENGAN EN CUENTA QUE NUNCA la presión y/o la temperatura máximaaconsejadaNOTIENEQUESERSUPERADA,yaquepodríadañary/ocausarrupturasy/o pérdidasy/oaveríasdelproductoy,porlotanto,representarunriesgoyunpeligropotencialpara la seguridad, la saludad y/o la propiedad. A continuación Les proporcionamos los datos técnicos relativosalainstalacióndelosproductosdegriferíaGessi. ► L apresióndeejercicionotienequeserinferiora0,5bar(7,25psi)ysuperiora5bar(72Psi).Encaso depresionesdeejerciciomayores,utilicenunaválvuladereduccióndelapresión. ►Presiónmáximadeensayodurantelainstalación:8bar(116psi). ► E vitengrandesdiferenciasdepresiónentrelaalimentacióndelaguafríayaquelladelaguacaliente. Lasdiferenciasdepresión,elaguaconunalatocontenidomineralylassustanciasjabonosaspueden...
  • Page 5 PRE-INSTALLATION INFORMATION - PRÉALABLES - PRELIMINARES ART. 59090...
  • Page 6 PRE-INSTALLATION INFORMATION - PRÉALABLES - PRELIMINARES Before installation and setting to work Attention! The feeding pipes have to be rinsed thoroughly before the installation of the mixer, so that no shavings, welding or hemp residual or other dirt can be found in the pipes. Foreign bodies can enter the mixer through the rinsed pipes or the general water plant and could damage the washers/ring washers.
  • Page 7 PRE-INSTALLATION INFORMATION - PRÉALABLES - PRELIMINARES Package content: Contenido de la caja: A - Fastening bushes A-Bujedefijación B - Finish plates for handles B - Placas embellecedoras para manetas C - Control handles C - Manetas de mando D - Supply spout D-Cañodeerogación E - Spout support E-Soporteparacaño...
  • Page 8 PRE-INSTALLATION INFORMATION - PRÉALABLES - PRELIMINARES 1/8” [3 mm] 1/8” 13/16” [2,5 mm] [20 mm] 1/16” [2 mm] - Installation tools - Outils nécessaires pour l’installation - Herramienta necesaria para la instalación...
  • Page 9 INSTALLATION - INSTALLATION - INSTALACIÓN Fig. 1 Fig. 2 Fig. 3 1/8” [3 mm]...
  • Page 10 INSTALLATION - INSTALLATION - INSTALACIÓN Fig. 4 13/16” [20 mm] Fig. 5 1/16” [2 mm] Fig. 6 1/8” [2,5 mm]...
  • Page 11 INSTALLATION - INSTALLATION - INSTALACIÓN Fig. 7 1/8” [3 mm] Fig. 8 1/8” [2,5 mm]...
  • Page 12 WORKING - FONCTIONNEMENT - FUNCIONAMIENTO Fig. 9 COLD...
  • Page 13 MAINTENANCE - ENTRETIEN - MANUTENCIÓN MAINTENANCE •   S houlditbenecessarytoreplaceoneormorecomponents,contactanauthorized retailerorvisitWWW.GESSI.COM •Productmaintenanceshouldbemadeonlybyqualifiedstaff ENTRETIEN • S ’ilestnécessairederemplacerunouplusieurscomposants,contacteruncentre autoriséouvisiterlesiteWWW.GESSI.COM •L’entretienduproduitnedoitêtreeffectuéquepardupersonnelqualifié MANUTENCIÓN • E nelcasodequeseanecesarioremplazarunoomáscomponentes,contacten conunrevendedorautorizadoovisitenelsitioWWW.GESSI.COM •Encarguensóloapersonalcalificadoparaelmantenimientodelproducto...
  • Page 14 MAINTENANCE - ENTRETIEN - MANUTENCIÓN HEADVALVE REPLACEMENT - SUBSTITUTION DE LA TÊTE - SUSTITUCIÓN DE LA MONTURA Fig. 22 Fig. 23 1/8” [2,5 mm] 1/16” [2 mm] Fig. 24 Fig. 25 1/8” 13/16” [2,5 mm] [20 mm] Fig. 26 11/16” [17 mm]...
  • Page 15 MAINTENANCE - ENTRETIEN - MANUTENCIÓN ALIGNMENT OF CONTROL HANDLES - ALIGNEMENT DES POIGNÉES DE COMMANDE - DE LAS MANETAS DE MANDO Fig. 1 Fig. 2 11/16” [17 mm] Fig. 3 Fig. 4 CLOSE Fig. 5 Fig. 6 M6x40min. SCREW - Not supplied...
  • Page 16 MAINTENANCE - ENTRETIEN - MANUTENCIÓN ALIGNMENT OF CONTROL HANDLES - ALIGNEMENT DES POIGNÉES DE COMMANDE - DE LAS MANETAS DE MANDO Fig. 7 Fig. 8 Fig. 9 Fig. 10 13/16” [20 mm] 1/8” [3 mm] Fig. 11 Fig. 12 1/8” [2,5 mm] 1/16”...
  • Page 17 MAINTENANCE - ENTRETIEN - MANUTENCIÓN ALIGNMENT OF CONTROL HANDLES - ALIGNEMENT DES POIGNÉES DE COMMANDE - DE LAS MANETAS DE MANDO Fig. 13...
  • Page 18 MAINTENANCE - ENTRETIEN - MANUTENCIÓN AERATOR CLEANING / REPLACING - NETTOYAGE / SUBSTITUTION DE L’AERATEUR - LIMPIEZA / SUSTITUCIÓN DEL AIREADOR Fig. 14 Fig. 15 Supplied Fourni Incluido en el suministro...
  • Page 20 GIS005250-R1...