Connection and Operation
Check for matching voltage specifications on the inverter and the desired load devices.
Always unwind the DC cable completely before operating the device. Check for adequate air clearances at the ventilation slots to
ascertain sufficient cooling. Never cover the ventilation slots and never operate the device near combustible materials.
Connect the inverter with the DC power supply and switch it on. If everything is connected properly and operated within specified
parameters, the green LED will light up.
General notes on operating AC loads with inverters
In general, all AC loads may be operated with inverters. To estimate the power requirements and necessary reserves, one needs to
know some characteristics of typical AC loads. Most AC loads have been designed for mains operation. One important item to note
however is the required inrush current which does not play a big role when operated on mains voltage since the mains grid is capable
of delivering very large currents. Manufacturers therefore do not focus on inrush current. The inrush current however may exceed the
nominal rated value by a multiple.
Incandescent lamps up to 8x higher inrush current within 1 sec
Refrigerators up to 10x higher inrush current within 3 sec
Television sets up to 10x higher inrush current within 1 sec
Therefore it is important to choose the inverter for sufficient power reserves. For example an inverter supposed to supply a small
refrigerator of 50W nominal power has to deliver a peak power of 500W.
Reverse Polarity Protection
In case the DC input is accidentally connected with reversed polarity the current is flowing across a diode and triggers the fuse. In this
case the proper polarity must be established and the fuse replaced.
Replacing the Fuse
The underside of the device holds a fuse. In case the fuse is blown the inverter has to be disconnected and the fuse replaced with a
new one of the same current rating. Subsequently check the device without any load connected. In case the fuse blows again the
device is defective and has to be repaired by an authorized technician.
Technical Data
Rated voltage DC
Input range
Max. input current
Switching on threshold
Switching off threshold
Low voltage – advance warning
Input rating in open-circuit/no-load operation
DC fuse protection
Continuous output rating
Output rating 30 min.
Peak output rating
Output voltage AC
Frequency (+/-1%) at 12V/24V DC IN
Max. output current (continuous/peak)
Efficiency factor:
Input
Output power outlet
Dimensions in mm
Weight
Environmental protection information
When no longer in use, this product may not be deposited in the normal household waste but should be brought to a
collection point for the recycling of electrical and electronic appliances. A symbol on the product, the operating instructions
or the packaging draws attention to this. The materials are recyclable as marked. By re-use, recycling or another form of
using old appliances you are making an important contribution towards the protection of the environment.
Please ask your local authorities for the appropriate disposal point.
We reserve the right to make technical alterations. We assume no liability for typing errors. 09/2007
Tel: 09622 – 719910; Fax: 09622 – 7199120; info@ivt-hirschau.de; www.ivt-hirschau.de
SW-100 12V
0,45/0,9 A
cigarette lighter
IVT Innovative Versorgungs-Technik GmbH, Dienhof 14, D-92242 Hirschau
12V
11-15V
10 A
12,5V
10,5V
11,5V
2,5VA
1 x 15A
100VA
120VA
200VA
225V
50 Hz
eff
> 88 %
1 x Euro
170 x 50
0,5 kg