M1000E
Pressing of the FUN (yellow) key at any time causes system to exit from data transfer mode and to return to the function selection menu.
If the FUN (yellow) key is pressed while data is being transferred, the system in any case completes transfer of the code being processed, after which
it exits from this mode and returns to the function selection menu.
Diagram of terminal strips and keys
Note: Make sure that terminals 5 and 7 are bridged in order to enable the relay output. This contact is particularly useful to enable, for instance, the
relay output of the M1000E via external devices such as buried magnetic coils (M1000E enabled only in case of a vehicle being present on the coil so
as to avoid undesired operations caused by accidental radio transmission) or via timed relays (M1000E enabled within a given time interval), as well
as for closing the normally open contact of a switch, and so on.
Note: The input to force the activation of the single door (terminal 6) is active if referred to GND.
DECLARATION OF CONFORMITY
Hereby, PRASTEL S.p.A., declares that M1000E is in compliance with the essential requirements and other relevant provisions of Directive
1999/5/EC.
The complete declaration of conformity is available in Prastel.
ENGLISH
1
Antenna
2
Relay - N.C. contact
3
Relay - Comman contact
4
Relay - N.O. contact
5
Relay enabling
6
Relay activation (REX)
7
GROUND
8
IWiegand data input (DATA1)
9
IWiegand data input (DATA0)
10
External reader power supplì (9Vdc)
11
Power supply (12-24 VAC/DC)
12
GREEN: VAL (Confirm)
RED: DEC (Decrement location)
BLUE: INC (Increment location)
YELLOW: FUN (Access to function menu)