Before Starting The Equipment - Pro Work PBH 850/1 Mode D'emploi D'origine

Masquer les pouces Voir aussi pour PBH 850/1:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 15
Anleitung_PBH_850_1_SPK1:_
GB
The hammer drill is not designed for outdoors use as
specified I Article 3 of Directive
2000/14/EC_2005/88/EC.
Wear ear-muffs.
The impact of noise can cause damage to hearing.
Total vibration values (vector sum of three directions)
determined in accordance with EN 60745.
Hammer drilling in concrete
Vibration emission value a
= 21.748 m/s
2
h
K uncertainty = 1.5 m/s
2
Chiseling
Vibration emission value a
= 15.183 m/s
2
h
K uncertainty = 1.5 m/s
2
Additional information for electric power tools
Warning!
The specified vibration value was established in
accordance with a standardized testing method. It
may change according to how the electric equipment
is used and may exceed the specified value in
exceptional circumstances.
The specified vibration value can be used to compare
the equipment with other electric power tools.
The specified vibration value can be used for initial
assessment of a harmful effect.
Keep the noise emissions and vibrations to a
minimum.
Only use appliances which are in perfect working
order.
Service and clean the appliance regularly.
Adapt your working style to suit the appliance.
Do not overload the appliance.
Have the appliance serviced whenever
necessary.
Switch the appliance off when it is not in use.
Wear protective gloves.
Residual risks
Even if you use this electric power tool in
accordance with instructions, certain residual
risks cannot be rules out. The following hazards
may arise in connection with the equipment's
construction and layout:
12
16.09.2010
10:54 Uhr
Seite 12
1. Lung damage if no suitable protective dust mask
is used.
2. Damage to hearing if no suitable ear protection is
used.
3. Health damage caused by hand-arm vibrations if
the equipment is used over a prolonged period or
is not properly guided and maintained.

5. Before starting the equipment

Before you connect the equipment to the mains
supply make sure that the data on the rating plate
are identical to the mains data.
Always pull the power plug before making
adjustments to the equipment.
Check the drilling point for concealed electrical
cables, gas and water pipes using a cable/pipe
detector.
5.1 Additional handle (Fig. 2 – Item 6)
For safety reasons you must only use the
hammer drill with the additional handle.
The additional handle (6) enables you to achieve
better stability whilst using the hammer drill. The
machine must not be used without the additional
handle (6) for safety reasons.
The additional handle (6) is secured to the hammer
drill by a clamp. Turning the handle anti-clockwise
(looking from the handle) will release the clamp.
Turning the handle clockwise will tighten the clamp.
First release the additional handle clamp. You can
then swing the additional handle (6) into the most
comfortable working position for you. Now turn the
additional handle in the opposite direction again until
the additional handle is secure.
5.2 Depth stop (Fig. 3 – Item 7)
The depth stop (7) is held in place by the additional
handle (6) by clamping. The clamp can be released
and tightened by turning the handle.
Release the clamp and fit the depth stop (7) in
the recess provided for it in the additional handle.
Set the depth stop (7) to the same level as the
drill bit.
Pull the depth stop back by the required drilling
depth.
Turn the handle on the additional handle (6) until
it is secure.
Now drill the hole until the depth stop (7) touches
the workpiece.

Publicité

Table des Matières
loading

Table des Matières