7. Restore Operation Function
Restore Factory Settings
When the controller is powered on and in non-setting parameter status, please press
buttons simultaneously on the main controller and release until the screen turns o automatical-
ly. Wait for the equipment to restart automatically and restore to factory settings.
8. Technical Parameters
Working voltage: 100~240VAC, 50/60Hz
Temperature measurement range: -5~70°C / 23~158°F
Temperature control range: -5~70°C / 23~158°F
Temperature measurement accuracy: ±0.5°C /±1°F
Temperature resolution: 0.1°C /0.1°F
Humidity measurement range: 5~99%RH
Humidity control range: 5~99%RH
Humidity measurement accuracy: ±5%RH
Humidity resolution: 0.1%RH
Relay contact output capacity: 10A (resistive) / 100 ~ 240VAC
Output power: 2200W (resistive) in total / 200W (inductive) per channel @220VAC,
1100W (resistive) in total / 100W (inductive) per channel @110VAC
Total power consumption: <5W
Working environment temperature: 0°C~60°C / 32~140°F
Storage temperature: -10°C~70°C / 14~140°F
Length of power probe: 1.5m
Length of output power probe: 0.3m
Enclosure size: 165 x 60 x 32 mm
Length of sensor cable: 2m (including probe length)
Best viewing angle of LCD screen: 6 O'clock direction