Technical data Spirocom wireless

Ingress protection
Rating
Note
IP67
For sealed unit, excluding microphone.
Frequency
Region
Frequency
Europe
868 MHz
USA
915 MHz
Approvals
Approval
Note
CE
Approved
FCC
ID: YDFSCMBT34320
IC
8937A-34320
The mask mounted unit is intrinsically safe
Region
Note
Europe
GA Exia IIB T4, -30°C - + 60°C
USA
UL913, for use in Class I, II, III, Division 1, Group C to G Hazardous Locations
Substitution of components may impair Intrinsic safety.
This device complies with part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) This device may not cause harmful interference,
and (2) this device must accept interference received, including interference
that may cause undesired operation. Changes or modifications not expressly
approved by the party responsible for compliance could void the user´s
authority to operate the equipment. This equipment has been tested and found
to comply with the limits for a Class A digital device, pursuant to part 15 of the
FCC rules. These limits are designed to provide reasonable protection against
harmful interference with the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the instruction manual,
may cause harmful interference to radio communication. Operation of this
equipment in a residential area is likely to cause harmful interference in which
case the user will be required to correct the interference at his own expense.