Smoke detector
Product specifications
Battery:
Alarm output:
Operation temperature:
Operation humidity:
Quiescent current:
Alarming current:
Dimensions:
Weight:
LED indicator:
Hush status:
Standby status:
Low battery status:
and need battery replacement
Installation
Choose an appropriate position to install the alarm on a ceiling
away from obstructions, doors, windows, ventilator and
radiator and at least 50cm from fluorescent lights and low
energy bulb.
Use the screws and plugs provided to secure the installation
panel securely to the ceiling.
Align the 2 locating slots in the smoke detector with the 2 tags
on the installation panel and rotate it clockwise until it locks
into position.
Testing and usage
Turn the smoke detector anti-clockwise to remove it from the
installation panel.
Install the 9V battery supplied and ensure it is clipped behind
the red security arm at the side of the panel.
Align the 2 locating slots in the smoke detector with the 2 tags
on the installation panel and rotate it clockwise until it locks
into position.
1 x 9V 6F22
≥85dB/3m
-10°C - 40°C
≤95% Relative humidity
with no water condensing
≤12µA
≤20mA
36mm x 102mmØ
140g
Red LED
LED flashes every 10s
LED flashes every 43s
Beep around every 43s