the suffix "W-A" ("W" in Canada) to
indicate it is OK for outdoor use.
6.
Make sure the extension cord is
properly wired and in good electrical
condition. Always replace a damaged
extension cord or have it repaired by
a qualified electrician before using it.
7.
Protect the extension cords from
sharp objects, excessive heat, and
damp or wet areas.
Recommended minimum wiRe
gAuge FoR eXtension coRds*
(120/240 Volt)
eXtension coRd
nAmeplAte
AmpeRes
(at full load)
0 – 2.0
18
2.1 – 3.4
18
3.5 – 5.0
18
5.1 – 7.0
18
7.1 – 12.0
18
12.1 – 16.0
14
16.1 – 20.0
12
* Based on limiting the line
tABle A
voltage drop to five volts at
150% of the rated amperes.
symbology
Double Insulated
Canadian Standards Association
Underwriters Laboratories, Inc.
V~
Volts Alternating Current
A
Amperes
No Load Revolutions per Minute
n 0 xxxx/min.
(RPM)
SKU 97580
For technical questions, please call 1-800-444-3353.
All manuals and user guides at all-guides.com
lengtH
18
18
18
16
18
18
16
14
18
16
14
12
16
14
12
12
14
12
10
-
12
10
-
-
10
-
-
-
Page 8