2.5. Reset to default settings
Disable the camera's power supply
Press and hold the reset key
Continue to hold the reset key and enable the
camera's power supply
When the LED starts flashing (after approx. 15
- 30 seconds), you may let go of the key
The following settings must be performed
again after the reset:
(only 20-2906A-IP/21-2906A-IP/43-9588/
20-2913A-IP/21-2913A-IP/50-2906A-IP)
1. Assign camera password
2. Capture Mode: 1080P (1920x1080)
www.behnke-online.com
Configuration and set-up
3.Powerline frequency: 50 Hz.
4. system/plain configuration/network/
network HTTP: basic
5. Wide dynamic range: off
only 43-9582:
▸1. Assign camera password
▸2.Powerline frequency: 50 Hz.
▸3. HTTP/RTSP Password Settings:
unencrypted only
!
These settings should only be
carried out if sufficient knowledge
of the AXIS web frontend is
available.