OPERATING INSTRUCTIONS (XE-70M CONTROLLER)
Page 7 – Analog Outputs
Figure 27 : Analog inputs
Analog Outputs ( Not available on this compressor
model) :
The value for the analog outputs will be in mA��
VSD Blower Output – Current speed of the VSD
•
blower (if installed)��
Page 8 – CT Inputs
Figure 28 : CT Inputs
CT Inputs
Displays the mA value of the current transformers
installed on each leg of the motor incoming power
CT1
•
CT2
•
CT3
•
FACTORY SETTINGS FOLDER
This folder is for Ingersoll Rand factory and service
personnel�� A password must be entered on page one in
order to adjust values in this folder�� This folder is used for
setting parameters that are specific to that compressor
and displaying software information for the controller��
Page 1 – Password
Figure 29 : Password
RELEASED 20/Jul/2016 17:56:55 GMT
All manuals and user guides at all-guides.com
Password:
Provides access to enter a valid password to gain access
to password protected parameters�� The password is
entered by scrolling down to the password value and
pressing the return key��
Password entered:
This checkbox will indicate a valid password has been
entered�� If this checkbox is blank, a valid password has
not been entered or it has timed out�� This is read only��
Password timeout enable:
Checking this box will enable the password time feature��
Password timeout:
This timeout along with the password timeout enable
allows the user to set an adjustable amount of time
to require a valid password to be re-entered�� Once
this timeout is reached re-entry of a valid password is
required�� The timeout counter is reset after any button
press��
Pages 2 Thru 6 – Factory Settings
Figure 30 : Factory settings
80448418 Rev.C