Combi 05-12-25
INSERTING AND CHANGING THE LAMP
WARNING: Always disconnect from the
mains supply prior to opening the units
to change the lamp.
Open the luminaire lid by means of knob ⑥. Insert the
lamp into the socket taking care not to touch the glass
and reposition the lid.
WARNING:
To mount a 1000W lamp (with a lower
centre of light), instead of the 1200W lamp, the pan
fitted with the lamp holder must be shifted from the
low Ⓑ position to the high position Ⓐ (see diagram)
after rotating the retaining spring ⑧. Re-position the
spring at the end of the operation.
SWITCHING ON AND FOCUSING
Using the side handle ⑤ it is possible to loosen
the projector when it is locked in a certain position
and thus change its inclination. You can rotate the
luminaire on the vertical axis by rotating it on its hook
clamp.
By turning knob ⑨, the lamp carriage is shifted forward
or backward to widen or narrow the beam of light
respectively.
TYPE OF LAMP
Please consult the enclosed table for lamps to be used.
CLEANING
For maximum projector performance, keep the lens and
the mirror as clean as possible using a dampened cloth
with alcohol.
MAINTENANCE
At least once a year, the luminaire should be serviced
to ensure the integrity of the electrical and mechanical
components.
RECYCLING
The product must be recycled or disposed of,
according to Directive 2002/96/CE.
All manuals and user guides at all-guides.com
6