7.3 Tank level issue – problème avec la mesure de réservoir.
Step
Control
1
Identify the measure block (grey icon with the number 7) at the network view.
If there is no block seven at the network view, check directly at his plug if it is
supplying (plug 19 and 21).
If OK step 2
2
Identify the input on which the setting page measure is (page 9 and 10).
Check the level directly at the page SETTING below the icon.
If level at 0%, step 3
3
Check the sensor directly at the input.
Disconnect the 21 ways connector and check the sensor value with an ohmmeter.
Clean water and fuel → resistive probe 0-190Ω
Tank empty 0Ω, tank full 190Ω
Grey and black water → resistive probe 240-30Ω
Tank empty 240Ω, tank full 30Ω
If faulty, check the wiring and the probe and change it if defect.
If probe and wiring are ok, change the block seven.
Etape
Contrôle
1
Identifier le bloc de mesure (icone gris avec le numéro 7) dans la vue réseau.
S'il n'y a pas de bloc 7 sur la vue réseau, contrôler son alimentation directement à ses
bornes (bornes 19 et 21).
si OK étape 2
2
Identifier l'entrée sur laquelle la mesure est configurée (page 9 et 10).
Contrôler le niveau directement à la page des réglages en dessous des icones.
Si le niveau est de 0%, étape 3
3
Contrôler la sonde directement à l'entrée.
Déconnecter le connecteur 21 voies, contrôler à l'aide d'un ohmmètre la valeur de la
sonde.
Sonde d'eau propre ou de fuel → sonde résistives 0-190Ω
Réservoir vide 0Ω, réservoir plein 190Ω
Eaux grise et noires → sonde résistives 240-30Ω
Réservoir vide 240Ω, réservoir plein 30Ω
S'il n'y a pas de valeur ohmique, contrôler le raccordement et la sonde puis changer
la si elle est défectueuse.
Si la sonde et le raccordement sont ok, procéder au remplacement du bloc 7.