Possible causes of faults, and their remedies
Problem
Permanent message:
"poor/no signal"
Only UB 9: "poor/no
signal"
Short message:
"Poor/no signal" or
picture wobbles in
regular intervals
Loop-through multi-
switches without
Kathrein Power
Saving do not or only
sometimes function
Electronic equipment is not domestic waste - it must be disposed of properly in
accordance with directive 2002/96/EC OF THE EUROPEAN PARLIAMENT AND THE
COUNCIL dated 27
ances. At the end of its service life, take this device for disposal at a designated public
collection point.
Internet: www.kathrein.de
KATHREIN-Werke KG • Anton-Kathrein-Straße 1-3 • P.O. Box 10 04 44 • 83004 ROSENHEIM • GERMANY • Phone +49 8031 184-0 • Fax +49 8031 184-306
All manuals and user guides at all-guides.com
Possible cause:
No voltage from
receiver
Wrong single-cable
command
Poor DiSEqC™
signal
Wrong PIN Code
Wrong assignment
No voltage on the
LNB
Receiver does not
support SCD2
conforming to
prTS50607
Another subscriber
has accessed the
same UB
Stand-by switch on
"ON"
January 2003 concerning used electrical and electronic appli-
th
936.4552/a/VKDT/0713/GB - Technical Data subject to change
Solution
Short circuit on the receiver – multi-switch
connection. Receiver is not in single-cable
mode. Outlet blocks permanent 18 V.
Receiver is not in single-cable mode
Power consumption too high. Use distribu-
tion material without diodes. Use NCF 18
power supply unit for EXE 259.
Check or deactivate PIN code number
UB and frequency do not match.
Warning: SCR no. is not equivalent to UB no.
EXE 159 mains plug not plugged.
Short circuit on the receiver – LNB connection
If possible, perform software update on
receiver
Check menu settings of all connected
receivers. Check that frequencies are as-
signed to one receiver only.
Switch off stand-by function.
Stand-by switch to "OFF"