Télécharger Imprimer la page

Ultraflex UP 56 Manuel D'installation Et D'entretien page 15

Publicité

Les langues disponibles

Les langues disponibles

ULTRAFLEX
3
Screw the fittings (3) on the pump with a torque of
50 Nm (36,9 lb ft) by using an open end wrench 22 mm.
CAUTION
Do not use Teflon, Loctite or similar products on the
fitting thread since they have a seal.
4
By using the proper template provided with
KIT KIM56, make the holes (4) required by the
installation in the suitable position on the
dashboard.
5 Position the pump (2) on the dashboard front
side (5) and fix it by inserting the 4 washers (6)
and by tightening the 4 self-locking nuts (7) with
a 17 mm wrench and a torque of 16 Nm (11,8
lb ft).
CAUTION
If the self-locking nuts are disassembled (7), they
must be replaced. (Contact our assistance
service, see page 6).
WARNING
Install the pump by positioning the filling hole
(8) towards the top (see the picture) for the right
pump operation and to allow filling and purging
the system completely (see par. 3.7).
Installation and Maintenance Manual
System fitting
3
Connection for additional
station
4
5
8
2
PUMP FOR HYDRAULIC SYSTEMS
Connection
for
additional station
3
System fitting
7
6
6
7
7
7
6
6
page 15
-
of 75

Publicité

loading

Ce manuel est également adapté pour:

Up 68