4.5
Setting the motor protector
See Figure 4. Check the rated current on the fan motor identification plate and
set the motor protector (see X) in the Fan Contactor accordingly.
NOTE!
Lockable safety switches are recommended for the whole electric
system including the fan.
CAUTION!
The switch B must point on "0" before power connection.
4.6
Resetting the motor protector
Break the power supply, remove the cover on the Fan Contactor and push the
button C, see Figure 5.
5
Using Fan Control Series 591
See Figure 5. The system is designed to be used in a dry environment in
combination with other Nederman products for extracting fumes, smoke or dust.
5.1
Automatic regulation of fan
(Only products with sensor.) Fit the sensor clamp on the welding cable. Check
before welding begins that the sensor clamp is in place.
The sensor stops the fan automatically after completion of welding with a
delay time of approximately 1 min. (could be adjusted). The sensor responds to
welding currents from 8 to 400 A. The sensor has a LED (A) which indicates
when the sensor has received a signal.
5.2
Manual regulation of fan
The fan can be started or stopped with the switch B or with the switch on the
fume extractor hood.
WARNING!
Risk of personal injury.
• Check, after the products has been installed, that there is enough suction
capacity in the ducting system before any work has begun. Check the fan
impeller rotation direction.
• The equipment is not to be used in an explosive environment.
6
Maintenance
Installation, repair and maintenance work is to be carried out by qualified
personnel using only original Nederman spare parts. Contact your nearest
authorized distributor or Nederman for advice on technical service.
6.1
Spare parts
Contact your nearest authorized distributor or Nederman for advice
on technical service or if you require help with spare parts. See also
www.nederman.com. When ordering spare parts always state the following:
•
Part number and control number (see the product identification plate).
•
Detail number and name of the spare part (see www.nederman.com).
•
Quantity of the parts required.