Removing the trigger
• Disconnect the airline from the tool.
• Remove all fasteners from the magazine.
• Remove the rubber grommet (8) from the end of
the dowel pin (9).
• Remove the dowel pin.
• Remove the trigger assembly (10).
Fitting the trigger
• Insert the trigger assembly into the trigger cavity,
ensuring that the trigger spring (11) is properly
seated.
• Insert the dowel pin (9) through the tool frame,
contact trip guide and trigger assembly.
• Push the rubber grommet (8) onto the end of the
dowel pin.
Air fitting (fig. A)
These tools have a standard 3/8" pipe thread for the
air fitting (7).
• Wrap the male end of the fitting with Teflon tape
to prevent air leaks.
• Screw the fitting into the end cap and tighten firmly.
Loading the tool (fig. C)
• Lock the magazine latch (6) in the back position.
• Select an appropriate collated fastener stick.
See „Technical data".
• Place the collated fastener stick (s) onto the
magazine rail (11).
• Release the magazine latch by unlatching the
lever (12).
• Carefully slide the latch forward to press against
the fasteners.
Unloading the tool (fig. C)
• Lock the magazine latch (6) in the back position.
• Remove the collated fastener stick (s) from the
magazine rail (11).
Always disconnect the tool from the air
supply before loading or unloading
fasteners.
Adjusting the driving depth (fig. D)
The driving depth can be adjusted to the type of
fastener used.
• To reduce the depth, press the lock button (12)
and slide the slider (3) downward.
All manuals and user guides at all-guides.com
• To increase the depth, press the lock button (12)
Trigger lock (fig. A)
This tool is equipped with a trigger lock-off switch
which prevents the tool from firing a fastener.
• To engage the trigger lock, push the switch (2) to
• To release the trigger lock, push the switch to the
Instructions for use
Preparing the tool (fig. A)
• Drain all condensation from the air compressor
• Lubricate the tool. See „Maintenance".
• Remove all fasteners from the magazine.
• Check if the contact trip (4) can move freely.
• Check that the pressure of the air supply is below
• Connect the air hose to the fitting on the tool.
• Check for audible leaks around valves and gaskets.
• Set the air pressure to the minimum required
Cold weather operation
When operating tools at temperatures below freezing:
• Keep the tool as warm as possible before use.
• Disconnect the airline from the tool.
• Put 10 to 15 drops of D
• Set the air pressure to a maximum of 5.5 bar.
• Connect the air hose to the fitting on the tool.
• Load fasteners into the magazine as described
• Actuate the tool 5 or 6 times into scrap lumber to
and slide the slider (3) upward.
the right.
center.
Always observe the safety instructions
and applicable regulations.
tanks and hoses.
Do not use the tool if the contact trip
cannot move freely.
the maximum recommended operating pressure.
operating pressure for your application.
Never use a tool that leaks or has
damaged parts.
E
(or winter-weight pneumatic oil containing
ethylene glycol) into the air inlet.
above.
lubricate the o-rings.